Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Withdrawable;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 40.5kv;
Rated Frequency: 50/60Hz;
Truck Type: Vacuum;Isolation;Fuse.;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection, RCCB;
Standard: IEC/En 62606 & IEC 61009-1;
Tripping Curve: B,C,D;
Rated Current (in): 6A,10A,16A,20A,25A,32A,40A;
Residual Current Type: Type AC,a;
Residual Current (LΔn): 30mA,100mA,300mA;
Making Breaking Capacity (IΔm): 2,000A;
Energy Limiting Class: 3;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1/2/3/4;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Rated Voltage: 230V(1p/2p) 400V (3p/4p);
Rated Current: 6A,10A,16A,20A,25A,32A,40A,50A,63A;
Over-Current Protection: 100% Alert,110% Trip,Adjustable Threshold;
Short-Circuit Protection: 5-10 Rated Current for 0.04 S for Circuit Break;
Overload Protection: 100% Alert,110% Trip,Adjustable Threshold;
Over-Voltage Protection: 110% Alert,120% Trip,Adjustable Threshold;
Under-Voltage Protection: 90% Alert,80% Trip,Adjustable Threshold;
Over-Temperature Protection: 80ºC Alert,100ºC Trip,Adjustable Thresh;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection;
Product Name: Moulded Case Circuit Breaker;
Standrad: IEC60947-2/GB14048.2;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Voltage Ui: 500V AC;
ICU: 10ka;
Frame Current: 63A;
Rated Working Voltage: Normal Voltage;
|