Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: SF6;
Installation: Fixed;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Control Cabinet;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Open Frame;
Structure: VCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Local & Remote Control Available;
Rated Voltage: 11kV;
Rated Current: 630A~1250A;
Rated Frequency: 50/60Hz;
Breaking Current: 20kA~25kA;
Poles: Three;
Control: with Control Cabinet;
Certificate I: ISO9001 Certified;
Certificate II: CE Certified;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed & Withdrawable Types;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Current: 630A, 1250A, 1600A, 2000A, 2500A, 3150A, 4000A;
Rated Voltage: 12/24kv;
Mechanical Edurance: 30000 Cycles;
Rated Frequency: 50/60 Hz;
Assembly: Common Insulated Cylinder;
Short Circuit Breaking Current: 20~40ka;
Phase Distance: 150mm/210mm/275mm;
Operation Type: Fixed & Withdrawable;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Open Frame;
Structure: ACB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 400/690VAC;
Electrical Life(Time): 500-10000times;
Material: ABS+Copper Busbar;
Standard: IEC60947-2;
Operate Way: Auto Parts;
Warranty: 2 Years;
Range: Protect Building;
Thermal Adjust: 40%-100%;
Magnetic Adjust: 400%-1000%;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Open Frame;
Structure: ACB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 400/690VAC;
Electrical Life(Time): 500-10000times;
Material: ABS+Copper Busbar;
Standard: IEC60947-2;
Operate Way: Auto Parts;
Warranty: 2 Years;
Range: Protect Building;
Thermal Adjust: 40%-100%;
Magnetic Adjust: 400%-1000%;
|