Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio, Power Transmission distribution;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Transformers;
Reference Standards: IEC60076 ANSI GB DIN EN IEEE PN SR JIS;
Capacity: 630~25000kVA;
Rated H. V.: 10kv;
Rated L. V.: 0.42kv;
Impedance: 4-8%;
Cooling Way: an/Af;
Winding: Cooper/Aluminum;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Enclosure: IP20/IP23;
Accessories: Fans, Enclosure, Monitering unit;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Shore-to-ship power supply;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Oil Immersed Distribution Transformer;
Application scenario: Wind Turbines;
Capacity: 4000kVA;
Rated H. V.: 22kV;
Rated L. V.: 6.6kV;
Impedance Voltage: 4~6 %;
Frequency: 50Hz/60Hz;
Cooling Way: ONAF/ONAN;
Tapping Range: +2X0.25% /-2X0.25%;
Core Material: Silicon Steel/Amorphous Alloy;
Winding Material: Copper/Aluminium;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Oil Immersed Distribution Transformer;
Application scenario: Wind Power Nacelle;
Capacity: 1600kVA;
Rated H. V.: 11kV;
Rated L. V.: 0.433kV;
Impedance Voltage: 4~6 %;
Frequency: 50Hz/60Hz;
Cooling Way: ONAF/ONAN;
Tapping Range: +2X0.25% /-2X0.25%;
Core Material: Silicon Steel/Amorphous Alloy;
Winding Material: Copper/Aluminium;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Oil Immersed Distribution Transformer;
Application scenario: Wind Turbines;
Capacity: 2000kVA;
Rated H. V.: 22kV;
Rated L. V.: 0.8kV;
Impedance Voltage: 4~6 %;
Frequency: 50Hz/60Hz;
Cooling Way: ONAF/ONAN;
Tapping Range: +2X0.25% /-2X0.25%;
Core Material: Silicon Steel/Amorphous Alloy;
Winding Material: Copper/Aluminium;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Three-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Amorphous Dry Type Transformer;
Capacity: 1000KVA;
Primary Voltage / Secondary Voltage: 6.6/0.4kV;
Frequency: 50/60Hz;
Tapping Range: +2X2.5%/-2X2.5%;
Impedance: 4~8%;
Application Scenario: Traction Unit;
Vector Group: Dyn11 or Yyn0 (Customized);
Winding Material: Copper/Aluminium;
Core Materials: Amorphous Alloy;
Insulation Material: Cast Resin;
Temperature Rise: 125K;
Accessories: Cooling Fans, Enclosure ,Temperature Control;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T10228, GB1094.11, IEC60076-11, DIN42523;
|