Specification |
Application: Power, Instrument, Lighting;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Qinghao;
Standard: IEC60076 / GB1094;
Connection Group: Y,Yn0/D,Yn11;
Product Name: Oil Immersed Transformer;
Warranty: 24 Months;
Frequency: 50/60Hz;
Logo: Qinghao or Customized;
Tapping Method: on Load / off Load Tapping Changer;
Material: Copper / Aluminium;
Transformer Type: Oil Filled Transformer;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 11kv/12kv/20kv/33kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 30kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 110kv 220kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 11kv/12kv/20kv/33kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|