Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p,2p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 500V AC;
ICU: 10ka;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Insert;
Structure: Vcb;
Poles Number: 3;
Type: Vacuum Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Handcart/Fixed;
Rated Short-Circuit Breaking Current: 20,25,31.5,40,50ka;
Rated Short-Time Withstand Current: 20,25,31.5,40,50ka;
Rated Short Circuit Duration: 4s;
Contact Stroke: 3~4mm;
Mechanical Life (M2): 10,000~20,000times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Insert;
Structure: Vcb;
Poles Number: 3;
Type: Vacuum Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Handcart/Fixed;
Read Short Circuit Breaker Current: 20ka,31.5ka,40ka;
Read Short Circuit Making Current(Peak)U: 50ka,80ka,100ka;
Mechanical Life: 100000 Times;
Rated Short-Circuit Duration: 4s;
Rated Voltage: 12kv;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Insert;
Structure: Vcb;
Poles Number: 3;
Type: Vacuum Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Handcart/Fixed;
Rated Peak Withstand Current: 50,63,80ka;
Rated Short-Circuit Breaking Current: 20,25,31.5ka;
Clearance Between Open Contacts: 12~14 mm;
Contact Stroke: 3~5mm;
Mechanical Life (M2)Mechanical Life (M2): 10,000(20,000)Times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Insert;
Structure: Vcb;
Poles Number: 3;
Type: Vacuum Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Short Circuit Breaking Current: 20,25,31.5,40ka;
Rated Peak Withstand Current: 50,63,80,100ka;
Lightning Impulse Withstand Voltage: 125kv;
Mechanical Life: 20000 Times;
Contact Travel: 12-14mm;
|