Specification |
Cooling Method: Water Cooling;
Unit Model: SD300s;
Normal Power: 345/275(kVA/Kw);
Standby Power: 375/300(kVA/Kw);
Engine Model: Sc13G420d2;
Fuel Consumption Rate: 200g/Kw.H;
Speed Regulation Mode: Electronic Control;
Number of Cylinders: L6;
Cylinder Bore: 135mm;
Trip: 150mm;
Displacement: 12.88L;
Oil Capacity: 33L;
Total Coolant Capacity: 68L;
Overall Dimensions: 3010X1650X1820(mm);
Weight: 2900kg;
Noise: <115dB(a);
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500 /1800rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Rated Voltage: 220/380V 230/400V;
Controller: Smartgen / Deepsea / Comap / Dkg / Others;
Rated Current: Base on Data;
ATS System: Smartgen / ABB / Socomic / Others;
Frequency: 50/60Hz;
Rated Power: 30kw;
Engine: Zh4100zd-42kw;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Standby Unit;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Rated Power: 728kw/910kVA;
Standby Power: 800kw/1000kVA;
Engine Model: 728kw/910kVA;
Alternator: Stam-Ford, Marathon, Leroy Somer, Yhg;
Controller: Smartgen, Deepsea, Comap, Datakom, Harsen, etc;
Insulation Class&Protection Class: Class H/F;IP21-23;
ATS: for Option;
Fuel Tank: 8-10 Hours Running Time for Full Load;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Standby Unit;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Rated Power: 1000kw/1250kVA;
Standby Power: 1100kw/1375kVA;
Engine Model: 1000kw 1250kVA;
Alternator: Stam-Ford, Marathon, Leroy Somer, Yhg;
Controller: Smartgen, Deepsea, Comap, Datakom, Harsen, etc;
Insulation Class&Protection Class: Class H/F;IP21-23;
ATS: for Option;
Fuel Tank: 8-10 Hours Running Time for Full Load;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Standby Unit;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Rated Power: 1080kw/1350kVA;
Standby Power: 1188kw/1485kVA;
Engine Model: 1080kw/1350kVA;
Alternator: Stam-Ford, Marathon, Leroy Somer, Yhg;
Controller: Smartgen, Deepsea, Comap, Datakom, Harsen, etc;
Insulation Class&Protection Class: Class H/F;IP21-23;
ATS: for Option;
Fuel Tank: 8-10 Hours Running Time for Full Load;
|