Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Installation: Panel Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: RJ45;
Measured Signal: 333mv CT, Rogowski Coil;
Type: Power Meter;
Customized: Customized;
Input Type: External CT(333mv Only), External Rogowski Coil;
Poles Description: 3p3w, 3p4w;
Frequency Range: 50/60Hz;
Application: Current,Voltage,Power,Energy and Harmonic Measurem;
Display Screen: 3.8 Inch LCD Segment Code Display Screen;
Current Sensor Type: 333mv CT, Rogowski Coil;
Advantage: 3 in 1 Current Sensor with RJ45 Port;
Primary Rated Current: 5A, 100A, 600A, 2500A, 6000A;
Secondary Rated Input: 333mv, 50mv/Ka@50Hz, 85mv/Ka@50Hz;
Recommended Sensor: STP CT, STP Rogowski Coils;
Voltage Range: 0~600VAC Phase to Phase Voltage;
Communication: Modbus RTU, RS485 Port;
Power Supply: 95~265VAC/110~260VDC, 45~60Hz;
Maximum Power Consumption: 3.5va;
Data Refresh Rate: 500ms;
|
After-sales Service: Free;
Warranty: 18 Month;
Display: Indicator;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Customized;
Product Name: Local Communication RS485 Electric Energy Meter;
Voltage: 3*220/380V;
Current: 3*1.5(6)a;
Frequency: 50Hz;
Accuracy Class: Active Cl.1, Reactive Cl.2;
Impulse Constant: 12000imp/Kwh;
Communication: IR,RS485 Modbus;
Operation Temp.: -20~+70 Degree;
Relative Humidity: <90%;
Starting Current: 0.002ib;
Power Consumption: <2W, <10va;
|
Display: Indicator;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Customized;
Product Name: Three Phases Four Wires Energy Meter;
Voltage: 3*220/380V;
Current: 3*1.5(6)a;
Frequency: 50Hz;
Accuracy Class: Active Cl.1, Reactive Cl.2;
Impulse Constant: 12000imp/Kwh;
Communication: IR,RS485 Modbus;
Operation Temp.: -20~+70 Degree;
Relative Humidity: <90%;
Starting Current: 0.002ib;
Power Consumption: <2W, <10va;
|
Display: Indicator;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Customized;
Product Name: Three Phase RS485 Energy Meter;
Voltage: 3*220/380V;
Current: 3*1.5(6)a;
Frequency: 50Hz;
Accuracy Class: Active Cl.1, Reactive Cl.2;
Impulse Constant: 12000imp/Kwh;
Communication: IR,RS485 Modbus;
Operation Temp.: -20~+70 Degree;
Relative Humidity: <90%;
Starting Current: 0.002ib;
Power Consumption: <2W, <10va;
|
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Reference Voltage: 3*220/380V;
Rated Current: 3*5(80)a;
Impulse Constant: 1000imp/Kwh;
LCD Display: LCD6+2;
Relative Humidity: < 95%;
Rated Frequency: 50Hz;
Accuracy Class: Cl.1;
Communication: RS485, IR Communication;
Protocol: Dlt645-2007;
Standards Compliant: IEC62053-21, IEC62052-11;
|