Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Color OLED;
Installation: DIN Rail;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Rogowski Coil, Voltage-Output Current Clamp;
Type: Energy Meter;
Customized: Customized;
Application: Power Analysis/Energy Measure/ Event Data Record;
Supported Current Sensor: Rogowski Coil, Voltage-Output Current Clamp;
Storage: 16GB Micro SD Card, USB Data Download;
Primary Side Current Range: 600A, 3000A, 6000A;
Power Supply: Electricity From Major Loop, 90-528VAC;
Connecting Terminal Type: SATA Interface, Terminals;
ABC Voltage Measurement Accuracy: 0.2%(5-528V AC);
Temperature: 3 Channels(Optional);
Humidity: 1 Channel;
Frequency: 0.01%(45-65Hz);
Communication: Modbus TCP & Modbus RTU;
Harmonic: 51 Times;
Data Format: Csv;
Optional 1: on-Line Power Quality Monitoring Platform;
Optional 2: 4G Edge Processing Gateway;
|
Display: Digital;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Multi-rate Watt-hour Meters;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Type: Power Meter;
Accuracy: Class 1.0;
Reference Voltage(V): 3 X 127/220, 3 X 230/400;
Current Specifications(a): 5(50), 5(100), 5act;
Insulation Performance: AC Voltage 4kv for 1 Minute;
|
Display: LCD;
Type: Power Meter;
Number of Channels: 4u/4I.;
Phase-to Phase Voltage: 1.0V~2000V;
Phase-to-Neutral Voltage: 1.0V~1000V;
Current: 10mA~ 6000A at Option;
Frequency: 40Hz~70Hz.;
Parameters of Electricity: W, Va, Var, PF, DPF, Cos, Tan.;
Energy Parameters: Wh, Varh, Vah.;
Harmonic: Order 0~50.;
Total Harmonic Distortion: Order 0~50, Each Phase.;
Expert Mode: Yes.;
Input Impedance: Input Impedance of Test Voltage: 1mohm;
Withstand Voltage: Withstand 3700V/50Hz Sinusoidal AC Voltage for 1 M;
Insulation: Between Instrument Wiring,Shell More Than10mohm;
Structure: Double Insulation, with Insulation Vibration-Proof;
Safely Rules: IEC 61010 1000V Cat III / 600V Cat IV, IEC61010-03;
|
Usage: Watt-Hour Meter;
Electric Equipment: Single-phase;
Theory: Static Meter;
Type: Energy Meter;
Accuracy: Class 1.0;
Rated Voltage(V): 220~240;
Rated Current(a): 2.5(10), 3(15), 5(30), 10(50), 15(90), 20(100), 5(;
Stareing Current: 0.4%Ib, 0.5%Ib;
|
Display: Indicator;
Usage: Watt-Hour Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Induction Meter;
Type: Energy Meter;
Accuracy: 1.0, 2.0;
Reference Voltage(V): 3X230/400, 3X127/220, 3X230/400, 3X220, 3X400;
Current(a): 1.5(6), 5(20), 10(40), 20(80), 30(120);
Starting Current(a): 0.1, 0.15;
|