Specification |
Classification: Imaging Diagnostic Equipment;
Type: Ultrasound Scanner;
Group: All People;
Model: Convex Probe with Type C Port;
Probe Type: Convex;
Imaging Mode: B-Mode, Pw-Mode;
Gray Scale Level: 256;
Frequency: 3.5MHz(2.5-4.5MHz);
Body Mark: 140;
Ultrasound Software: Yes;
Application: Ob/Gyn, Urology, Abdomen, Emergency and ICU;
Elements: 128 Elements;
Scanning Methods: Electronic Linear, Convex, Sector;
Measure: Distance, Area, Volume, Ellipse, etc;
Power Consumption: 1W;
Maximum Frame Rate: 20 Fps;
Cine Review: 100 Frames;
Image Save: JPG, Dicom;
|
Classification: Imaging Diagnostic Equipment;
Type: Digital Imaging System;
Group: All;
Model: Bk-HS32;
Extraction Method: Magnetic Beads;
Sample Capacity: 32;
Processing Volume: 20-1000μl;
Extraction Time: 15min-60min;
Magnetic Bead Recovery: ≥98%;
Extraction Difference Between Wells: <3%;
Magnetic Rod Flux: 4500GS;
Temperature Range: Adjustable Heating Function, Rt;
Module Station: 2;
Disinfection Method: 8W UV Lamp;
Illuminating Lamp: 3.4W LED Lamp;
Operation Interface: 10.1 Inch Capacitive Touch Sc;
Barcode Scanning Function: Optional External Barco;
Project Storage: >1000;
|
Classification: Imaging Diagnostic Equipment;
Type: X Ray Equipment;
Scintillator Type: Gos;
Image Sensor: a-Si(Amorphous Silicon) TFT;
Active Area Size: 350×427 mm ±0.5;
Active Area Pixel: 2496×3040 Pixels;
Pixel Size: 140 μm;
Spatial Resolution: 3.4 Lp/mm;
Imaging Time: 5 S;
Preview Time: 3 S;
|
Classification: Medical Lab Equipment;
Type: Biochemistry Analyzer;
Group: All;
Usage: Medical Lab, Clinic;
Test Project: ≥70;
Wavelength: 450,492,510,546,578,630nm;
Flow Cell: 32UL,Quartz Glass;
Liquid Volume: 200-3000UL;
Resolution: 0.001ABS(Display); 0.0001ABS(Calculation);
Carryover: Less Than 1%;
Repeatability: Less Than 1%;
Printer: Internal Thermal Printer, 58nm Paper Width;
Display: 240*64LCD;
Communication: RS-232 Serial Cable;
Dimension: 380mm(L)*330mm(W)160mm(H);
Weight: 7kg;
|
Classification: Medical Lab Equipment;
Type: Biochemistry Analyzer;
Group: All;
Usage: Medical Lab, Clinic;
Test Mode: Kinetic, End Point, Two Point, Absorbance;
Wavelength: 7 Standard Filters, 340, 405, 492, 510, 546, 578;
Wavelength Precision: ±2 Nm, Width ≤ 10nm;
Absorbance Range: 0~4.500 ABS;
Absorbance Precision: Outside 0.0001 ABS, Inside 0.00001 ABS. Carry Over;
Repeatability CV: Less Than 1%;
Sample Volume: 0~3000 UL (≥500UL Recommend);
Data Storage: ≥10000;
Flow Cell: 32 UL Quartz Glass, 10 mm;
Lamp: Philips 6V 10W Halogen Lamp with Long Life;
CPU: Arm Series High Speed Micro CPU;
Printer: Internal Thermal Printer;
Dimension: 340(L)*270(W)*160(H);
Weight: 5 Kg;
|