Sepcifications

  • Breaking Capacity Low Voltage Circuit Breakers
  • Operation Electric Type
  • Speed Normal Type Circuit Breaker
  • Arc-extinguishing Medium Air
  • Installation Insert
  • Structure MCB
  • Poles Number 1p+N,2p,3p,3p+N,4p
  • Certification ISO9001-2000, CE, CB, CCC
  • Transport Package Export Packing
  • Specification IEC/EN 60898-1, CE, 3C, CB
  • Trademark CNC
  • Origin Zhejiang, China
  • Rated Voltage (V) 230
  • Rated Current (a) 1,2,3,4,6,10,16,20,25,32,40
  • Rated Frequency(Hz) 50/60
  • Dielectric Test Voltage(Kv) 2.0
  • Rated Breaking Capacity(a) 4500/6000
  • Rated Impulse Withstand Voltage(V) 4000
  • Insulation Voltage(V) 500
  • Protection Degree IP20
  • Curve B,C,D
  • Mechanical Life 8000

Product Description

CNC Hot Product Residual Current Circuit Breaker Replace The Dz47 (YCB6h-63) Product Description 1. Overload protection 2. Short circuit protection 3. Controlling 4. Used in residential building, non-residential building, energy source industry and infrastructure 5. According to the type of ...

Learn More

MCB Comparison
Transaction Info
Price Negotiable Negotiable US $ 12.00-250.00/ Piece Negotiable US $ 3.50-10.00/ Piece
Min Order 1 Box 1 Pieces 10 Pieces 1 Pieces 100 Pieces
Trade Terms FOB, CFR, CIF, EXW - - - -
Payment Terms L/C, T/T L/C, T/T, Western Union, Paypal L/C, T/T, Western Union L/C, T/T, Western Union, Paypal L/C, T/T, D/P, Western Union, Paypal, Money Gram
Quality Control
Product Certification ISO9001-2000, CE, CB, CCC ISO9001-2000, CE, CCC ISO9001-2000, CE, CCC ISO9001-2000, CE, CCC ISO9001-2000, CE, CB, CCC
Management System Certification ISO 9001, ISO 9000, ISO 14001 ISO 9001, ISO 14001 ISO 9001, ISO 9000, ISO 14001, ISO 14000 ISO 9001, ISO 14001 ISO 9001, ISO 14001, ISO 50001
Trade Capacity
Export Markets South America, Europe, Southeast Asia/ Mideast North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe Domestic North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Annual Export Revenue - - - - -
Business Model OEM, ODM, Own Brand OEM, ODM OEM, ODM OEM, ODM OEM, ODM, Own Brand
Average Lead Time Off-season: within 15 Day(s)
Peak-season: within 15 Day(s)
Off-season: within 15 Day(s)
Peak-season: within 15 Day(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: within 15 Day(s)
Off-season: within 15 Day(s)
Peak-season: within 15 Day(s)
Product Attributes
Specification
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCB;
Poles Number: 1p+N,2p,3p,3p+N,4p;
Rated Voltage (V): 230;
Rated Current (a): 1,2,3,4,6,10,16,20,25,32,40;
Rated Frequency(Hz): 50/60;
Dielectric Test Voltage(Kv): 2.0;
Rated Breaking Capacity(a): 4500/6000;
Rated Impulse Withstand Voltage(V): 4000;
Insulation Voltage(V): 500;
Protection Degree: IP20;
Curve: B,C,D;
Mechanical Life: 8000;
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Vacuum Circuit Breaker;
Rated Voltage: 12kv;
Rated Frequency: 50Hz;
Mechanical Life: 10000 Times;
Rated Current: 630A;
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Operation Voltage: 400/415V;
Standard: IEC60947-2;
Rated Insulation Voltage: 800V;
IR: 10in;
Cat.: a;
Uimp: 8ka;
Ui: 100V;
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Vacuum Circuit Breaker;
Rated Voltage: 12kv;
Rated Frequency: 50Hz;
Mechanical Life: 10000 Times;
Rated Current: 630A;
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Rated Frequency: 50/60 Hz;
Bcd Curve: C;
Protection Grade: IP20;
Operating Temperature: -20ºC~+70ºC;
Flashover Distance: ≥50;
Supplier Name

Changcheng Electrical Group Zhejiang Technology Co., Ltd.

China Supplier - Diamond Member Audited Supplier

Shenheng Power Equipment Co., Ltd.

China Supplier - Diamond Member Audited Supplier

Xiamen Ninewan Trade Co., Ltd

China Supplier - Gold Member Audited Supplier

Shenheng Power Equipment Co., Ltd.

China Supplier - Diamond Member Audited Supplier

Zhejiang Zhiyi Electric Co., Ltd.

China Supplier - Gold Member Audited Supplier