Specification |
After-sales Service: Lifelong;
Warranty: 1 Year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
Item: Phdc100;
Model No.: Phdc100;
pH Range: 2-12pH;
pH Zero Point: 7.00±0.25;
Temperature Range: 0-80ºC;
Pressure Resistance: 0-0.3MPa;
Temperature Sensor: No;
Housing Material: PP+GF;
Membrane Resistance: <600mΩ;
Reference System: AG/Agcl/Kcl;
Liquid Junction: Ceramic Cores;
Electrolyte Solution: Kcl;
Double Junction: Yes;
Connection Thread: NPT3/4";
Cable Length: 5m or Customized;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
Model: Bk-Ea201;
Measuring Range: Hc:0~10000*10-6(Ppm)Vol Co:0~10*10-2(%)Vol;
Indicating Error: Hc±12*10-6(Ppm)Vol;
Stability: Moment Drift≤±3%;
Repeatability: ≤±2%;
Response Time: 95% Response Is Not More Than 10 Seconds;
Preheating Time: 8 Min (Preheating 3min Emergency Detection);
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Display: Digital;
Portable: Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
Parameters: Cond & TDS & Salt & Temp;
Range: 0.000us/Cm~400.0ms/Cm (Cond);
Resolution: 0.001 PS/Cm, 0.01 PS/Cm;
Accuracy: +0.5% F.S. (Cond);
Temp Range: -10.0-90.0 °c;
Temp Resolution: 0.1 °c;
Temp Accuracy: +0.2°cor+0.4%;
Atc: Auto;
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Display: Digital;
Portable: Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
pH/Mv: -2.00~16.00pH / -1999~+1999mv;
Conductivity: 0.00~200.0ms/Cm;
TDS: 0.00ppm~200.0ppt;
Salinity: 0.0~ 80.0ppt;
Temperature: -5.0~100.0ºC;
pH Temp Compensation: Auto / Manual -5.0~100.0ºC.;
Input Impedance: >1013 Ohms.;
Output / Memory Storage: RS232 or RS-232 to USB / 50 Sets;
|
After-sales Service: Yes;
Warranty: 1year;
Display: Digital;
Portable: Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
Product Name: Benchtop Mv ORP Temperature pH Meter;
Test Parameters: pH/Temp.(Mv/ORP);
pH Range: -2.000 to 20.000 pH;
Resolution: 0.1, 0.01, 0.001pH;
Accuracy: 0.002 pH;
Calibration Points: up to 6;
Standard Customization: Yes;
Calibration Reminder: Yes;
Standard Recognition: Nist, GB, DIN, USA, Merk, JIS Buffers;
Slope Limit: Yes;
Mv/ORP Range: -2000.00 to 2000.00 Mv;
Temperature Range: -10 to 135 C 14 to 275f;
Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous;
Temp. Compensation: Atc, Mtc;
Data Storage: 1000 Groups;
|