Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Under and Over Voltage Protection;
Rated Operating Current: 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Rated Operating Voltage: AC230V;
Electrical Life: > 100,000 Times;
Frequency: 50Hz;
Display: Indicator;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: ELCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB;
Standard: IEC61009,GB16917;
in: 6,10,16,20,25,32A;
Ue: 230V;
Rated Frequency: 50Hz;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC 60898.1 ; GB10963.1;
Ue: 230/400V;
in: 6, 10, 16, 20, 25, 32, 40, 50, 63A;
Pole: 1p2p3p4p;
Price: Factory Price;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB;
Standard: IEC 61009-1;
Pole: 3P;
Tripping curve: B,C,D;
Rated Current (in): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A;
Mode: Electronic;
Residual Current Type: AC;
Residual Current (LΔn): 30mA, 100mA, 300mA;
Icn: 6kA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
Keyword 1: circuit breaker;
Keyword 2: RCBO Breaker;
Keyword 3: RCBO;
Keyword 4: residuel current circuit breaker with overcurrent;
|