Specification |
Classification: Imaging Diagnostic Equipment;
Type: X Ray Equipment;
Group: Middle-aged and Old;
X-ray Generator: High Frequency DC at 20 kHz;
Anodic Voltage: 60-86 Kv;
Customization: Available;
After-Sales Service: Whole Using Lifetime;
Column Height: 230cm;
Vertical Movement: Manual Adjustment;
Warranty: 1year;
ODM: Available;
Power Supply: 220V, 50kHz;
Displacement: From 90 to 180 Cm;
Patient Positioning: Manual Carriage Adjustment;
|
Classification: Ophthalmic Equipment;
Type: Vision Field Analyzer;
Group: All;
Testing Scope: 90°;
Testing Distance: 30 Cm;
Background Light: White31.5asb, Yellow315asb;
Visual Target: 0.08 Asb -10000 Asb (0-51dB);
Visual Target Stimulation Time: 200 Ms;
Visual Target Interval Time: Standard and Custom;
Threshold Policy: Macula, 10-2, 24-2, 30-2, 60-4, Nasal Side;
Upper Threshold Policy: C-40, C-64, C-76, FF-81, FF-120, FF-135......;
Dynamic Policy: Standard Dynamic, Blind Dynamic, Dark Spot Dynamic;
Custom Policy: Static Custom Dynamic Custom;
Pupil Size Measurement: Auto;
Environment Light Testing: Auto;
|
Classification: Biochemical Apparatus;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Throughput: 400 Test/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic), Turbidimetry;
Sample Positions: 60 or 90 Sample Positions, Built-in Barcode System;
Reagent Positions: 90 Refrigerated Reagent Positions;
Sample Volume: 1-70μl;
Reagent Volume: 10-350μl;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: 2~8ºC;
Temperature Control: 37±0.1ºC, Real-Time Monitoring;
Cuvettes: 120 Reusable Cuvettes, Optical Length 6mm;
Mixer Probe: Independent Stirring;
Light Source: 12V/30W Halogen-Tungsten Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Calibration: Linear:K Factor, 1-Point ,2-Point and Multipoint L;
|
Classification: Biological Diagnostics;
Type: Automatic Biochemistry Analyzer;
Group: All;
Product Name: Automatic Biochemistry Analyzer;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Sample Volume: 2~70μl;
Reagent Volume: 20~350μl;
Probe: Liquid Level Sensor Function, Anti-Collision Funct;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37+0.1ºC, Real-Time Monitoring;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Light Source: 6V/10W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
|
Classification: Biological Diagnostics;
Type: Automatic Biochemistry Analyzer;
Group: All;
Product Name: Automatic Biochemistry Analyzer;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Sample Volume: 2~70μl;
Reagent Volume: 20~350μl;
Probe: Liquid Level Sensor Function, Anti-Collision Funct;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37+0.1ºC, Real-Time Monitoring;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Light Source: 6V/10W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
|