Specification |
Display: Digital;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: AC220V;
Warranty Period: One Year;
Standards: ISO 2759, ISO 2758;
Measuring Range: 250~5600kpa;
Indicating Accuracy: ±0.5% F.S;
Gross Weight: 67kg;
Dimension: 620(L)*420(W)*680(H)mm;
Packing: Wooden Box;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Moa Tester;
Display: LCD;
Power Source: AC220V;
Power Supply: Internal Lithium Battery or DC8.4V Adapter;
Leakage Current: 0-20mA (Extensible);
Voltage: 30-250V(Extensible);
Intensity: 30kv/M~300kv/M;
Angle: 0-306º;
Resistive Current: 0-20mA(Extensible);
Capacitive Current: 0-20mA(Extensible);
Lithium Battery Parameters: Charging Time > 2.5 Hrs;
Continuous Working Time: > 7hrs;
Interval Working Time: > 7×24hrs;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: at Customized;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: at Customized;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Partial Discharge Detector;
Power Source: AC220V;
Product Name: Partial Discharge Detector;
Channel: 4;
Sensitivity: 0.1PC;
Measurement Band: 3dB Bandwidth of 10kHz-1000kHz;
Lp: 10K,20K,40K,80K;
HP: 100K,200K,300K,1000K;
Gain Range: -20 dB ∽ +40 dB Fourth Gear;
Sampling Accuracy: 12bit;
Sample Rate: 10m /Sec.;
External Voltage Monitoring: RMS Voltage, 14-Bit a / D Accuracy;
Synchronization: Internal and External Optional, External Synchroni;
Sync Input Range: 10V --- 220V;
Linearity Error of The Range Stalls: Less Than 5% ± 1PC;
|