Rubber Cable, 300/500 V, Flexible Cu/Epr/CPE for mining
The cables are suitable for general use in dry, humid or moist situations outdoors: medium mechanical stresses, e.g. for industrial and agricultural appliances, heating installations providing that there is no risk of contact with hot parts and cable are not subject to radiation, electric tools such as drills and circular saws: and also transportable motors or machines on building sites or in agricultural workings and shipyards:
use in cold-storage applications; situations where the cable is subject to high abrasion and tear stresses. Also for hand-held inspection lamps.
The maximum conductor temperature in normal use is 90 ºC, and the lowest handling is -40 ºC.
STANDARD HD 22.10 / UNE 21027-10
TYPE OF COPPER ELECTROLYTIC ANNEALED COPPER CLASS 5 EN 60228
TYPE OF INSULATION RUBBER EPR TYPE EI-6 ACCORDING TO EN 50363-1
TYPE OF SHEATH POLYURETHANE TYPE TMPU ACCORDING TO EN 50363-10-2
TEMPERATURES -40ºC a +90ºC / +250ºC To Short Circuit
RATED VOLTAGE 300/500 V
SHEATH COLOURS DIFFERENT COLOURS
Specification Data
cross section area |
conductor diameter |
insulation thickness |
sheath thickness |
cable diameter |
weight |
DC resistance at 20° C |
n° x mm2 |
mm |
mm |
mm |
mm |
kg / km |
Ohm / km |
2 x 0,75 |
0,21 |
0,60 |
0,80 |
7,4 |
47 |
26,0 |
2 x 1,00 |
0,21 |
0,60 |
0,90 |
8,0 |
57 |
19,5 |
3 x 0,75 |
0,21 |
0,60 |
0,90 |
8,1 |
60 |
26,0 |
3 x 1,00 |
0,21 |
0,60 |
0,90 |
8,5 |
70 |
19,5 |
4 x 0,75 |
0,21 |
0,60 |
0,90 |
8,8 |
74 |
26,0 |
4 x 1,00 |
0,21 |
0,60 |
0,90 |
9,3 |
86 |
19,5 |
5 x 0,75 |
0,21 |
0,60 |
1,00 |
9,9 |
93 |
26,0 |
5 x 1,00 |
0,21 |
0,60 |
1,00 |
10,3 |
108 |
19,5 |
Package and Delivery
SERVICING
Purpose:
To establish and maintain a procedure for performing and verifying that our service meets specified requirements and that a suitable method of feedback exists from the customer back to the appropriate individual or department within YIFANG.
Scope:
YIFANG does not currently have any contracts that obligate the company to provide installation or service above and beyond normal product service and delivery. Service activity not specified by contract (such as the treatment of a customer complaint) shall be determined and performed free of charge on a case by case basis. Service concerns will be recorded and will provide a feed-back system as required by the customer.