Specification |
Application: Power;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Rated H.V.: 34.5/13.2/13.8/12.47/14.4/15/7.62/7.2kv;
Rated L.V.: 120/240/480/347/600V;
Frequency: 60Hz;
Winding Material: Copper/Aluminium;
Vector Group: II0/II6;
Applied Standard: IEC60076/IEEE/ANSI/DOE;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 50-2500kVA;
H.V. Winding: 10kv;
L.V. Winding: 0.4kv 0.415kv;
Vector Group: Dyn11 Dyn0;
No-Load Loss: 0.17-3.24kw;
Load Loss: 0.71-17.7kw;
No-Load Current: 1.0-2.6%;
Short Circuit Impedance: 4%;
Ambient Temperature: 40ºC -+ 40ºC;
|
Application: Power, Electric;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Power Transformer, Distribution Transformer, Utilities/New Energy;
Frequency Characteristics: 50/60Hz;
Shape of Core: Stacked Iron Core;
Brand: Daelim Belefic;
Type: Pole Mounted;
Winding Material: Copper/Aluminum;
Rated Capacity: 10kVA 15kVA 25kVA 37.5kVA 50kVA 100kVA 167kVA 333;
Warranty: 24 Months;
Standard: IEC/ANSI/IEEE/CSA;
Primary Voltage: 34.5kv 24.94kv 19.2kv 13.8kv 13.2kv 12.47kv;
Secondary Voltage: 240V 480V 600V;
Core Material: Silicon Steel;
Oil Type: Mineral or Vegetable Oil;
No Load Loss: 19W-350W;
MOQ: 6;
Vector Group: Dyn11/Yyn0/Yd11/Ynd11/Dyn5;
Customization: Accept;
Color: Gray or Customized;
Bil: 125/30kv or Others;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Dry Type Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Pengcheng;
Reference Standard: IEC60076/GB;
Capacity: 30kVA-2500kVA;
Rated H.V.: 6~16kv;
Rated L.V.: 0.4kv;
Impedance: 4.0%;
Cooling Way: an/Af;
Winding: Copper/Aluminum;
Core Materials: Silicon Steel;
Vector Method: Yyn0/Dyn11;
Grade of Insulation for Heat Resistance: Grade F or Above;
Temperature Rise: 125K;
Accessories: Fans, Enclosure;
|
Application: Power, Electric;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Utilities/New Energy;
Frequency Characteristics: 50/60Hz;
Shape of Core: Stacked Iron Core;
Brand: Daelim Belefic;
Product Name: Immersed Power Transformer 25000 kVA Transformer;
Rated Primary Voltage: 220kv 138kv 132kv 110kv 69kv 66kv 63kv 60kv;
Rated Secondary Voltage: 35kv 37kv 38.5kv 11kv 10.5kv 6.6kv;
Power: 20mva-200mva;
Frequency: 50Hz/60Hz;
Oil Type: Mineral or Vegetable Oil;
Standard: IEC ANSI IEEE;
Winding Material: Copper\Aluminum;
H.V. Tap Range: ±2*2.5%;
Impedance: 6.5, 10.5, 17~18 (%);
Customized: Accept;
Feature: High Frequncy Distribution Transformer Oil;
Connection Symbol: Ynd11 Ynyn0d11;
Short Circuit Impendence: 12-14;
Warrety: 24months;
|