Handheld Optical Power Meter with VFL(JF-H6301)
1.General
Optical Power Meter with VFL is a latest self-developed test instrument which to be used for absolute optical power measurement as well as loss relative measurement of fiber optic. It features ingenious appearance, large LCD display, auto-off function optional, wide range of power measurement, high accurate test precision, user automatic self calibration function and universal 2.5mm connetor. It is an ideal test instrument for optical fiber solution.
The Type of Handheld Optical Power Meter with VFL:
A type--- Wavelength:850 980 1310 1490 1550 1625nm
Measurment Range:-70~+6dBm,VFL Wavelength 650nm,Power 1mW
C type---Wavelength:850 980 1310 1490 1550 1625nm
Measurement Range:-50~+26dBm,VFL Wavelength 650nm,Power 1mW
2.Specification
Power Meter module | Parameter | Standard |
Wavelength(nm) | 850,980,1310,1490,1550,1625 |
Measurment Range(dBm) | A:-70 ~ +6 C:-50 ~ +26 |
Resolution | 0.01 |
Uncertainty (dB) | ±5% |
Data Storage Capacity | 500 Data record |
VFL module | Wavelength(nm) | 650 |
Output power (mW) | 1mW |
Fiber Identified Distance | >8km(Visible) |
Output Mode | CW |
Connector Type | 2.5mm universal Connector |
General Specification | Communication port | Mini USB |
Power Supply | lithium battery |
Operating hours | 28hrs(only power meter work) ≥4 hrs(Both work at same time) |
Operating temperature(°C) | -5~+60°C |
Storage temperature(°C) | -20~+70°C |
Warranty | 12 month |
Weight (g) | 300g |
Notice:
1 Measurement Range:can measure the maximum optical power range within specification.
2 Uncertainty:The error of test result between defined optical power and standard one.
3.Components
Handheld Optical Power Meter with VFL--------------------------------------1pcs
User Manual-----------------------------------------------------------------1book
USB Data wire-----------------------------------------------------------------1pcs
CD-ROM-----------------------------------------------------------------------1pcs
Power Adapter----------------------------------------------------------------1pcs
Protect Jacket-----------------------------------------------------------------1pcs
Lithium Battery---------------------------------------------------------------1pcs
Cleaning Cotton Swab--------------------------------------------------------1bag
VFLinterface,or as single optical power meter without the interface |
4.Functions
4.1 Keyboard Directions
Sign | Function |
MENU | Menu Key |
CANCEL | Withdraw from the current operation |
ENTER | Enter Key |
| Power on & off |
| Up key |
| Down key |
4.2 LCD display
LCD is displayed optical power value as dBm, mW, uW, nW(need to switch);and the battery power and automatic shut down state etc.
5.Usage Directions
5.1Power on/off
1.Press key on panel board,LCD display,Optical power meter is turned on.
2.Long press and hold key (about 3 seconds),to loose key,optical power meter is turned off.
5.2 Absolute Power Measurement
1.Switch on Optical Power Meter.
2. Enter intoMenu->Setting->Wavelength.OPM,Press up and down key to set wavelength,pressENTERkey to complete wavelenght setting.
3. Access the measured light,the screen will display the current measured value.
5.3 Relative Power Measurement
1.Setting the wavelength.
2. In the absolute power measurement mode, insert measured light, to measure the current power value.
3. Enter intoMenu->dB/dBm,and pressENTERkey,the main interface unit shown as dB,relative optical power value is 0dB.
4. Insert another to be measured light, it displays its current relative optical power value.
5.4 Save the testing value
After access to measured light signal,pressMenu->Save,and pressENTERkey to save the current test value.
5.5 check the test value was saved
Enter intoMenu->History,pressENTERkey to check the test data has been saved.
5.6 User Self-calibration
1. Enter intoMenu->Setting->Calibrate settings, then pressENTERkey.
2.Press up/down key to set calibration value,then pressENTERkey
5.7 Open the Visual Fault Locator
1. PressMenu->Setting->Wavelength.VFL,ThenENTER key.
2. Press up/down key to set VFL wavlength,then pressENTERkey.
Address:
Room 328, Building 10, No. 3599 Yuan Jiang Road, Min Hang District, Shanghai, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Industrial Equipment & Components
Management System Certification:
ISO 9000
Company Introduction:
Shanghai Jian Feng Photoelectric Technology Co., Ltd. Is specialized in the photoelectric field equipment and systems integration business integrated services, the main products are laser, optical fiber communications, optoelectronics, optical instruments, such as Photoelectric products design, introduction, research and development, technical consulting and sales.
Our main product:
Spatial Light Modulators, SLD light source, Laser Driven Light Source, THz time-domain spectrometer, CCD Spectrometer, Signatone, THz generator, PPXX bulk chip, Terahertz, Optical Coherence Tomography (OCT)
Our FOA (fiber optic amplifier), fiber laser, various light sources, fibre-optic transmission system, optical fiber sensing system, components and other products have been taking the lead in China.