Basic Info.
Application Fields
Chemical, Electronic, Food
Purification Method
Chemical Conversion
Purification technology
Electrostatic precipitator
Trademark
ZLLAB Carrier Bixiao gree
Specification
1500*850*2350mm 1800*850*2350mm PP, FRP, Stainles
Product Description
Product Description
In order to maintain the required temperature, humidity, wind speed, pressure, and cleanliness parameters in the clean room, the clean air conditioning system will continuously send a certain amount of treated air indoors to eliminate various thermal and humidity disturbances and dust pollution outside the clean room.
Basic composition:
The purification air conditioning system is basically composed of the following equipment
1. Heating or cooling, humidification or dehumidification, and purification equipment;
2. The air conveying equipment and pipelines that send the processed air into each clean room and circulate it;
3. Provide heat, cooling capacity, heat source, cold source and Plumbing to the system.
Clean air conditioning systems are generally divided into three categories:
1. Centralized clean air conditioning system: The purification air conditioning equipment required for a single or multiple clean rooms in the system is concentrated in the computer room, and clean air is distributed to each clean room through air supply pipes.
2. Distributed clean air conditioning system: Each clean room in the system is equipped with separate purification equipment or purification air conditioning equipment.
3. Semi centralized clean air conditioning system: In this system, there are both centralized purification air conditioning rooms and dispersed air handling equipment in each clean room. It is a combination of centralized processing and local processing.
People usually name the system based on the cleanliness of each clean room within the system, such as a 100 level purification air conditioning system, a 1000 level purification air conditioning system, etc. Sometimes, they are also distinguished based on the properties of the final stage filters of the system, including high-efficiency air purification systems, sub high-efficiency air purification systems, and medium efficiency air purification systems.
Sterilization methods | Functional segment length |
Electronic purification | 3M-8M |
activated carbon | Plate type 1M, carbon box type 4MM |
UV Germicidal lamp | 0M, does not occupy segment length |
Photocatalysis | 3M |
Ozone generator | 0M, placed in the air outlet section |
Traditional Plate Bag Filter | 1M, 5M |
The fan coil unit with fresh air system consists of fan coil units, fresh air units, temperature control switches, control components, and supply and return air devices. The general indoor air conditioning load is borne by the fan coil unit. When the air conditioning water passes through the fan coil unit, the indoor air circulating through the fan coil unit is subjected to cold and heat treatment to meet the changes in indoor load. Install a new air unit to provide fresh air for indoor personnel.
advantage:
The central cooling and heating source provides chilled/heating water, and the system has good stability;
The impact on the exterior facade of the building is relatively small;
The adaptability to the internal layout separation of the office and the decoration of secondary tenants is relatively flexible;
Maintenance and repair can be carried out by engineering property personnel without the need for professional manufacturer personnel to be present;
No need to occupy a large amount of roof and equipment floor area;
The lifespan of the device is longer than that of VRF (VRV), usually 15-20 years;
It is widely used in office buildings in China;
Centralized cold source has high energy efficiency.
Product Description
CAV Or VAV Exhaust System For Fume Hood Cupboard
CAV is the abbreviation for Constant Air Volume system. For a constant air volume (CAV) type fume hood, its ventilation volume is approximately constant. Therefore, when the operating door is pulled down, the speed will reach a high level in small areas. This difficult to control high-speed airflow will cause a short circuit in the airflow, which will be directly drawn away from the bottom surface and accumulate pollutants in a certain corner. On the one hand, it does not effectively dilute the pollutants inside the cabinet, and on the other hand, it directly causes energy waste. The improved bypass type fume hood can maintain a certain amount of airflow and wind speed by setting bypass louvers, but in reality, this is only relatively constant. Due to the use of fresh air in the laboratory, the energy consumption of fresh air treatment is quite high, and reducing ventilation as much as possible while ensuring a safe and comfortable working environment is undoubtedly the best way to save energy.
Product Description
Professional Variable Air Volume systems (VAV) fume hood designer and supplier.
Products Description:
Structure:
Made of thickness ≥1.2mm cold-rolled steel steel for the out layer, steel surface treated by acid-alkali-resistant and coated with epoxy resin powder. The inner layer is the anti-corrosion material.
Lining:
Lined with 5mm thick compact board (chemical resistant), segmented design, air flow pressure is maintained smoothly by teardrop-shaped baffle in accordance with aerodynamic principles.
Working surface:
Covered epoxy resin countertops or ceramic worktops with thickness ≥19mm, and the outer edge of not less than 25mm. The recessed 5mm inside disc design will collect splashes things. With high performance of anti-heat, chemical resistant.
Visual Windows:
Use 5mm tempered explosion-proof glass. lnternal uses of pituitary balancing device, can stay in any position during 0~900mm. Closure equipped with a rubber buffer.
Lighting:
Equipped with two (5-15W) LED energy-saving lamp. Lamp mounted on the top of hood and quarantined by the steam-proof glass cover inside the fume hood.
Transmission:
Windows Transmission system consists of a metal sprocket, plactis chains, synchronizing shafts and other devices. Balancing system prevents sash tilting and can be one- hand controlledSelection of the proper type of fume hood to use in a laboratory should be based upon two interrelated considerations: 1:The hood must allow the user to perform the work in a safe, efficient manner.
2. The need to reduce air conditioning cost.
The interior of the Penway`s hood resists the corrosive effects of chemicals. The hood under structure should provide for storage of the required chemicals for the work being done in the hood. The total cost of a hood is greatly affected by its exhaust air requirements. The annual cost of heating and cooling the air exhausted by the hood can be as high as the initial cost of the hood itself.
Choosing the proper hood type and sash configuration can significantly
reduce these costs. BARBINI (ZHONG LING) High-Performance/Low-Flow Fume HoodsCompared to most traditional fume hoods, these high performance, low flow hoods are safer, have lower installation costs, and are up to 50% less expensive in operating costs. We have designed and installed fume hoods in labs around the world. High performance fume hoods has a series of design features to provide unsurpassed containment and operator protection:1:Engineered baffle system provides proper air distribution2:Constant air velocity (variable air volume) reduces energy use relative to sash position3:Rounded corners at hood entrance reduce turbulence, improving efficiency4:Aerodynamic sash pull5:Containment trough with directional vanes and white Plascote finish adds durability and chemical resistance6:Cord pass-through lets sash fully close without appliance cords getting in the way7:Lower entrance safety bar provides a personal safety barrier 880mm high viewing area8:White ResChem interior with vapor-proof fluorescent light.9:458mm vertical opening with keyed sash stop to access 685mm set-up position10:Double-wall construction for installation of plumbing and electrical service fixtures.Advantages of High Performance Chemical Fume Hoods:
1:Engineered to exhaust 50% less conditioned air from the laboratory
2:Designed to capture fumes while working in today's modern laboratories with varying factors such as lab traffic, fluctuating temperatures and interior hood loading
3:Fume capture and containment can be demonstrated with tracer gas testing
5:Standard, available for all new chemical fume hood installations
6:Quiet operation
7:Low airflow provides an ideal environment for working with powders and delicate work.
Low-flow/high-performance hoods use substantially less energy to operate over the lifetime of the fume hood exhaust system. Visit Laboratory Fume Hood Energy Model to calculate your energy needs.BARBINI (ZHONG LING) has our own HVAC engineers to design the lab fume hood ventilation. From lab ventilation designs to construction, until system test and accept of work. BARBINI (ZHONG LING) can provide one-stop service to customer.The Variable Air Volume (VAV) air conditioning system and the Variable Air Volume (VAV) ventilation control system have a relatively stable wind speed of 0.5m/s, and the exhaust air volume changes with the opening and closing of the operating door. That is, when the door is wide open, the air volume increases; When the door is open, the air volume decreases and the wind speed remains constant. This ventilation control system can ensure the safety of the laboratory while also saving 40% -60% energy. Therefore, VAV variable air volume control systems have become very common in laboratories in developed countries. However, in recent years, China has just begun to attach importance to laboratories, and people are gradually accepting this new technology. We believe that in the future, VAV variable air volume systems will become a necessary consideration in Chinese laboratories. Objectively speaking, it is not easy to truly achieve comfortable and energy-saving operation of the VAV system. It has higher requirements for system debugging before delivery and later property use, requiring very professional and meticulous work in the debugging process. Even rework due to improper debugging is normal. Hefei Chengyue specializes in customizing solutions for laboratory CAV and VAV variable air volume ventilation control systems, with multiple patents.Hold hands once, be friends forever.BARBINI (ZHONG LING) can hardly grow without your support and help.Looking forward to cooperating with you.
Address:
Caojian Road 166, Shanghai, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Arts & Crafts, Chemicals, Construction & Decoration, Electrical & Electronics, Furniture, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Tools & Hardware
Management System Certification:
ISO 9001, ISO 9000
Company Introduction:
BARBINI INTERNATIONAL TRADING CO, . Ltd Established in 2019, specializes in the R&D, manufacturing, sales and after services of central air conditioner Home furnishings products.
With quality product and professional service, our customer group includes government building, office building, stadium, hotel, exhibition center, hospital, industrial products manufacturing factory, pharmacy factory, supermarket, automobile factory, mine industry, museum etc.
By continuous quality improving, we guarantee the clients high quality products, and maintain a healthy, stable and sustainable development.
The services which offered from BARBINI(ZHONGLING) Lab:
A-1: Lab furniture System.
2: Laboratory Renovation and Redecoration System
3: Decontamination and Air-Condition System in Lab
4: Laboratory Ventilation System (Fume Hood System)
5: Electrical Installation System
6: Lab Water Supply and Drainage System
7: Power Supply System
8: Central Gas Supply System in Lab
9: UPS Supply System
BARBINI INTERNATIONAL TRADING CO, . Ltd. BARBINI(ZHONGLING) Lab is a professional company that only focus on lab industry. Assembling the plan and design of integral laboratory, BARBINI(ZHONGLING) Lab provides One-Stop service for our customer, from lab planning & designs to lab construction we can offer a turnkey project service for the customers from all over the world.
The teams from BARBINI(ZHONGLING) Lab always try to find out the customers` special needs in the lab, then we start to design the whole projects according to the feedbacks from client. We believe that BARBINI(ZHONGLING) always can provide a safety and modern lab for our customers from all around the world.