Basic Info.
Main Application
Water, Wastewater, Corrosive Liquid/Gas
Application
Environmental Protection
Type
Electromagnetic Flow Meter
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Communication
RS485 Protocol 232 Hart
Output Signal
4-20macurrent
Category of Shielding
IP65, IP67, IP68
Rated Boltage
1.0MPa, 1.6MPa, 4MPa
Temperature of Medium
Loroprene Rubber:-10-60: PTFE:-10-120
Converter Type
Integral Type, Split Type, Insertion Type, Lamp Ty
Lining Material
Polyurethane Rubber, F4(PTFE)
Transport Package
Export Package
Product Description
electronic flow meter
Summary
electromagnetic flow meter with rs485 protocol,as the product of long-term
experience in the field of flow nstrument,has the functionsof rapid response and output
noise elimination,Its design and quality control systemhave guaranteed the high accuracy
and reliability of the product, and the application of lining makes the electromagnetic flow meter applied more widely.
Parameters
Aperture | 10-3200 |
Excitation System | Bidirectional Constant Flow Squarewave Excitation |
Installation Form | Integral or split |
Lining | Chloroprene Rubber,PTFE |
Material of Electrode | 316L,HC,HB,Titanium,Tantalum,Platiniridium |
Grounding | Built-in Grounding Electrode |
Medium | Conductive Liquid |
Grade of Accuracy | 0.3 ,0.5, 1.0 |
Flow Velocity | ≤15m/s |
Flange of Pipe Connection | GB9119-2000 or GB9115-2000 |
Pipe connection | Flange Connection |
Temperature of Medium | Chloroprene Rubber:-10-60ºC: PTFE:-10-120ºC |
Rated Boltage | 1.0MPa, 1.6MPa, 4MPa |
Cable Interface | G1/2 Female Thread |
Category of Shielding | IP65, IP68 |
Output Signal | 4-20mACurrent,Pulse, Warning beyond upper and lower limits |
Communication | RS485 Protocol |
Display of Monitor | Transient Flow,Percentage,Flow Velocity,Forward and Reverse Integrated Flux and Total Integrated Flux |
Power Supply | 220VAC, 24VDC |
Type of Application | General Type, Waterproof Type |
Order sheet
Name | Specification code | Explanation |
Instrument type | | Intelligent electromagnetic flow meter |
Diameter code | xxx | For example:100 represents DN100 |
Electrode form | 1 | Standard stationary type |
Electrode material | 0 | Stainless steel(316L) |
1 | Platinum Pt |
2 | Hastelloy B(HB) |
3 | Tantalum Ta |
4 | Titanium Ti |
5 | Hastelloy C(HC) |
Lining material | 3 | Chloroprene rubber |
4 | Polyurethane rubber |
5 | F4(PTFE) polytetrafluoroethylene |
6 | F46(FEP)polyperfluoroethylene-propylene |
Rated pressure(MPa) | 4.0 | DN10-80 |
1.6 | DN100-150 |
1.0 | DN200-1000 |
0.6 | DN1100-2000 |
0.25 | DN2200 |
Operating temperature | E | <80ºC |
H | <120ºC |
Grounding | | Built-in grounding electrode |
Grade of protection | 0 | IP65 |
1 | IP68 |
Converter type | 0 | Integral type |
1 | Split type |
Case material | 0 | Carbon steel |
1 | Stainless steel |
Instrument flange | 0 | Carbon steel |
1 | Stainless steel |
Installing timing flange | 0 | Withou |
1 | With |
Power supply source | 0 | 220VAC |
1 | 24VDC |
Instrument range | xxx | For example:(200)represents maximum fux corresponding to 20mA |
Flow :200mm³/h |
Address:
No 3 Hengshan Road, Yantai, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Instruments & Meters, Manufacturing & Processing Machinery
Management System Certification:
ISO 9000
Company Introduction: