Basic Info.
Product Description
Products Description Specially used to measure the height of the glass liquid level under various working conditions, for display and closed-loop control of the glass level . It can maintain high measurement accuracy and reliability in harsh environments. Use visible laser beam, easy to aim at the measured object. Various functional commands can be input by computer. The Digital output switch can be programmed The analog output range can be programmed . Freely set the output unit of the measured value . Trigger input function for special application.MSE-GL100 laser glass level gauge adopts phase comparison principle for measurement. The laser sensor emits visible laser beams of different frequencies, receives the scattered laser light returned from the measured object, compares the received laser signal with the reference signal, and finally uses the microprocessor to calculate the distance between objects corresponding to the corresponding phase shift. The measurement accuracy can reach mm level. Application | Glass liquid level / liquid level measurement, used to display and control liquid level |
Measuring range¹ | 0.1 ~ 10m |
Measurement accuracy ² | < 0.5 mm |
Resolution | 0.1 mm, user can set, the default setting is 1mm |
Repeatability | 0.3 mm |
Measuring Frequency | ≤ 10Hz |
Operating temperature | -10ºC~ +50ºC -40ºC~ +50ºC (with heating function, optional) -10ºC~ +70ºC (using water cooling + air purging) |
Storage temperature | -20ºC ~ +60ºC ( relative air humidity <70% ) |
Supply voltage | 24VDC ± 20% |
Power consumption | <1.5W (< 24W with heating function) |
Data interface. | RS232 (RS422 optional) baud rate 9600, ASCII format 8n1 |
Switching outputs | Programmable switch output, with load ≤ 0.5A |
Over-temperature alarm output. | Signal relay with a maximum load of 30VDC / 0.5 A. The load is required to use an Acoustic or / and Visual alarm (Power supply +24VDC, load current < 0.2 A) |
Analog output | 4...20mA, programmable for measuring range, load ≤ 500Ω |
Trigger input. | Trigger level 3~24V, pulse width >1ms |
Shock resistance | 10g / 6ms, DIN ISO 9022-3-31-01-1 |
Measuring laser | Wavelength 650nm (red), divergence angle 0.6mrad |
Laser class | Class 3R , with DIN EN 60825-1: 2014 standard, power ≤ 5mW |
MTBF | 30,000 hours, 24/7, if the internal working temperature of the sensor is +25ºC |
Dimensions (L×W×H) | 285×165×170.5mm (L×W×H) |
Weight | About 3.0kg (with 2m cable) |
Protection class | IP65 |
Scope of supply | Sensor, 2m cable, L-shaped mounting bracket, user manual book and USB-card |
Optional | Other interface, cooling jacket, junction box, additional diff. cables |
1.The measurement range is related to target reflectivity, stray light and environmental conditions 2. Statistical probability of measurement accuracy is 95% |
Address:
Kexin Building, 212 Changjiang Road,Yantai Development Zone, Shandong, China
Business Type:
Manufacturer/Factory, Other
Business Range:
Industrial Equipment & Components, Instruments & Meters
Company Introduction:
We are an engineering company in Yantai with German management and German investment. We develop, produce and market non-contact optical sensors and measuring systems for velocity, length, distance, width, thickness, level and position of cold as well as hot material.