Basic Info.
Model NO.
6ES7513-1AM03-0AB0
Product Description
Zhejiang Shuangkong Electric Technology Co., Ltd. is a high-tech enterprise specialized in the sales of industrial control automation products, system integration, electrical equipment sales and electromechanical equipment sales
Siemens programmable controller S7-200CN ET-200 S7-200 S7-300 S7-400 S7-1200 S7-1500 smartS7-200
Siemens touch screen OP77-TP series MP277 MP377 TD200-TD400C
Siemens communication accessories DP cable Ethernet cable DP connector communication card
Siemens motor V60-V80 servo motor 1FT servo motor Bede motor 1FK motor
Siemens inverter V10 series MM440 series G110 series G120 series
Siemens CNC system 810D system 840D system 808D 8404DSL
Siemens frequency converter series: MM420, MM430, MM440, G110, G120. MIDASTER series
Siemens full digital DC speed regulating device 6RA23, 6RA24, 6RA28, 6RA70, 6SE70 series
Siemens actuator, burner, controller, electric eye, flame detector, module, operation panel, etc
Siemens SQN, SQM, AGG, LFL, LME, LMV, QRA, SKP, VGD, VGF, VRD
Function
The faster SIMATIC S7-1500 controller provides higher functions. The processing time * of bit instructions is as low as 1ns, and the processing time * of floating-point operations is as low as 10ns (depending on the type of CPU, which is impossible in the products released for the first time). The speed of backplane bus is 40 times that of S7-400 PLC; Because the code generation is optimized, the response speed of the CPU is compared with the CPU of the existing manipulator.
Each CPU is equipped with a PROFINET IO (2-port switch) specification interface. CPU 1516-3PN/DP also has an integrated PROFINET basic interface, for example, it can be used for network blocking.
In addition to the integrated interface, each SIMATIC S7-1500 controller can also be expanded through communication module or communication processor. This provides many other connection methods, such as connecting through PROFIBUS, connecting through Ethernet, or connecting through the serial interface of the special protocol USS or Modbus RTU.
Integration skills
SIMATIC S7-1500 can integrate motion control function in PLC without any additional module. Through PLCopen, the manipulator provides standardized blocks that can be used to connect analog drives and PROFIdrive drives. The motion control function supports the speed axis, positioning axis and external encoder.
In order to effectively debug and quickly optimize the driver and closed-loop controller, SIMATIC S7-1500 also provides a wide range of tracking functions for all CPU variables, which can be used for real-time diagnosis and non-punctuality inspection.
In addition to the driver function, the S7-1500 also provides rich closed-loop control functions. For example, the control parameters can be actively optimized through a block that is easy to configure to obtain * good control quality.
In addition, technical modules can also be used to perform high-speed counting, azimuth acquisition and other functions, or to perform measurement for signals from 24V to 200kHz.
Integrated security functions
When working with STEP7, each CPU will provide common sense maintenance based on the cipher code to avoid unauthorized reading and changing the contents of the program block.
Copying maintenance strengthens security protection to avoid unauthorized copying of program blocks. The detailed program block can be connected to the serial number of the memory card, so that the program block can be performed only after the configured memory card is inserted into the CPU.
In addition, the controller has four different security visit levels to assign different visit permissions to different user groups.
Because of the improved operation and maintenance, the operator can detect data changes or unauthorized configuration data transmission.
The Ethernet communication processor (CP 1543-1) provides users with additional visit maintenance through the firewall, and can establish a secure VPN connection (V12SP1 and higher).
Planning and operation
All SIMATIC S7-1500 CPUs are equipped with a display screen. Through this display screen, the user can read the order number, firmware version and serial number of any module connected; In addition, the CPU IP address and other network settings can be adjusted locally without using programming equipment.
The fault message is displayed on the screen in the form of general text, which then helps to shorten the downtime.
All modules use the same front connector, and the integrated voltage jumper can form a sensitive voltage group, which simplifies the inventory.
Because the standard device guide rail is integrated in the S7-1500 device guide rail, it is convenient to install additional components such as active fuses and relays.
In the assembly equipment, the SIMATIC S7-1500 controller can be expanded through the signal module. In this way, through the expansion of space saving, you can be used to each application sensitively. When this kind of controller was introduced to the market, there were various analog and digital modules on the market.
The system cable kit used for digital signal module can be used to quickly and clearly connect the field sensor and executor (complete modular connection, including the front connector module, connector wire and connector module, and simple wiring in the switch cabinet (sensitive connection, including the front connector with pre-assembled single core).
In addition, the S7-1500 is also provided with a power module for supplying 24V voltage to the module and a system power supply for the internal module circuit.
Through IM 155-5 PROFINET interface module for ET 200MP I/O system, up to 30 signal, communication and technology modules can be used. Thus, the components and system strengths of S7-1500 are also applicable to distributed equipment. No matter whether the module is running in a centralized equipment next to the S7-1500 controller or in a distributed equipment completed by ET 200MP, users can't see any difference in operation and system functions. The high power backplane bus selected in these two systems can shorten the bus cycle time and response time, even for large station equipment and high quantity construction.
Integrated system diagnosis function
The diagnostic function of the integrated system has been pre-activated for the CPU of S7-1500 series; The system diagnosis information is uniformly displayed on the display screen, TIAPortal, HMI and Web server in the form of general text, and even the voice message from the frequency converter can be displayed; Now, this diagnosis will also be provided during the period of CPU outage. If new hardware components are equipped, the diagnosis information will be updated actively.
SIMATIC STEP 7 Professional V12 project configuration software
The new SIMATIC S7-1500 manipulator series can only be configured in the Totally Integrated Automation Portal using STEP 7 Professional V12 and higher. SIMATIC STEP 7 Professional V12 is an engineering configuration system for intuitive processing of SIMATIC S7-1500. In addition to configuring the S7-1500, it can also configure the S7-300/400 and S7-1200 controllers.
Compatibility
The porting integrated in SIMATIC STEP 7 Professional V 12 provides the following support:
Switch from S7-300/S7-400 to S7-1500 controller and actively change program code. Some program codes that cannot be changed actively will be recorded and can be modified manually. The STEP7V11 project can be used for STEP7 V12 in a compatible form. Moreover, the S7-1200 program can be changed to S7-1500 through posting/copying function.
SIMATIC memory card (used to run CPU)
SIMATIC S7-1500 CPU selects a SIMATIC memory card. The memory card is used as a thorn mount memory or to perform firmware updates.
This SIMATIC memory card can also be used to store STEP 7 items, including notes and symbols, other documents or csv files (for recipes and archiving). The system function (SFC) and user program can be used to create data blocks and store data on SIMATIC memory cards.
CPU module standard CPU 6ES75184AP000AB0 CPU 1518-4 PN/DP, 4 MB program, 20 MB data; 1 ns; Integrated 2x PN interface, 2x Ethernet interface, 1x DP interface
6ES75173AP000AB0 CPU 1517-3 PN/DP, 2 MB program, 8 MB data; 2 ns; Integrated 2x PN interface, 1x Ethernet interface, 1x DP interface
6ES75163AN010AB0 CPU 1516-3 PN/DP, 1 MB program, 5 MB data; 10 ns ; Integrated 2xPN interface, 1x Ethernet interface, 1x DP interface
6ES75152AM010AB0 CPU 1515-2 PN, 500 KB program, 3 MB data; 30 ns; Integrated 2x PN interface, 1x Ethernet interface
6ES75131AL010AB0 CPU 1513-1 PN, 300 KB program, 1.5 MB data; 40 ns; Integrated 2x PN interface
6ES75111AK010AB0 CPU 1511-1 PN, 150 KB program, 1 MB data; 60 ns; Integrated 2x PN interface
Compact CPU 6ES75121CK000AB0 CPU 1512C-1 PN, 250 KB program, 1 MB data; 48 ns; Integrated 2x PN interface; Integrated 32 DI/32 DO, 5 AI/2 AO, 6 HSC@100kHz
6ES75111CK000AB0 CPU 1511C-1 PN, 175 KB program, 1 MB data; 60 ns; Integrated 2x PN interface; Integrated 16 DI/16 DO, 5 AI/2 AO, 6 HSC@100kHz
Distributed CPU 6ES75121DK010AB0 CPU 1512SP-1 PN, 200KB program, 1 MB data; 48 ns; Integrated 1x PN interface (2 more PN interfaces can be expanded with ET 200SP bus adapter)
6ES75101DJ010AB0 CPU 1510SP-1 PN, 100KB program, 750 KB data; 72 ns; Integrated 1x PN interface (2 more PN interfaces can be expanded with ET 200SP bus adapter)
Open CPU 6ES76772AA310EB0 CPU 1515SP PC, 2 GB RAM, 8 GB CFAST; Pre-installed 32-bit WINDOWS EMBEDDED STANDARD 7 E, pre-installed CPU 1505S V1.7 software controller
6ES76772AA410FB0 CPU 1515SP PC,4 GB RAM,16 GB CFAST; Pre-installed 64-bit WINDOWS EMBEDDED STANDARD 7 P, pre-installed CPU 1505S V1.7 software controller
6ES76772AA410FK0 CPU 1515SP PC,4 GB RAM,16 GB CFAST; Pre-installed 64-bit WINDOWS EMBEDDED STANDARD 7 P, pre-installed CPU 1505S V1.7 software controller and WINCC ADVANCED RUNTIME (with 128-point authorization)
6ES76772AA410FL0 CPU 1515SP PC,4 GB RAM,16 GB CFAST; Pre-installed 64-bit WINDOWS EMBEDDED STANDARD 7 P, pre-installed CPU 1505S V1.7 software controller and WINCC ADVANCED RUNTIME (with 512 point authorization)
6ES76772AA410FM0 CPU 1515SP PC,4 GB RAM,16 GB CFAST; Pre-installed 64-bit WINDOWS EMBEDDED STANDARD 7 P, pre-installed CPU 1505S V1.7 software controller and WINCC ADVANCED RUNTIME (with 2048 point authorization)
Software controller 6ES76727AC000YA0 CPU 1507S, VERSION 1.8 (1 floating point authorization), can only be used on SIMATIC IPC
6ES78062CD000YA0 ODK for S7-1500 software controller, using C/C++to expand the functions of S7-1500 software controller
Bus adapter ET 200SP bus adapter 6ES71936AR000AA0 bus adapter BA 2 × RJ45
6ES71936AF000AA0 bus adapter BA 2 × FC Fast Connect
6ES71936AP000AA0 bus adapter BA 2 × SCRJ fiber
CPU communication module distributed CPU communication module 6ES75455DA000AB0 S7-1510/512 SP CPU DP communication module (RS-485 PROFIBUS-DP)
CPU memory card CPU memory card 6ES79548LC020AA0 S7-1200/1500 4M memory card
6ES79548LE020AA0 S7-1200/1500 12M memory card
6ES79548LF020AA0 S7-1200/1500 24M memory card
6ES79548LL020AA0 S7-1200/1500 256M memory card
6ES79548LP020AA0 S7-1200/1500 2G memory card
6ES79548LT020AA0 S7-1200/1500 32G memory card
Interface module ET 200MP interface module 6ES71555AA000AB0 ET 200MP IM 155-5 PN ST standard interface module
6ES71555AA000AC0 ET 200MP IM 155-5 PN HF high-performance interface module
6ES71555BA000AB0 ET 200MP IM 155-5 DP ST standard interface module
Power module Power management module 6ES75070RA000AB0 PS: 60 W, rated input voltage AC/DC 120/230 V
6ES75050RA000AB0 PS: 60 W, rated input voltage DC 24/48/60 V
6ES75050KA000AB0 PS: 25 W, rated input voltage DC 24 V
6EP1332-4BA00 PM 1507:72W, 24 V/3 A, rated output