Basic Info.
Application
Solar System Controller, Charger Controller, Lighting Controller, Wind Controller, Voltage Controller
Product Description
Wind/Solar energy complementary controller
Features
1. Use of CPU Intelligent Control
2. Multi-load operating modes: Light control, light control plus time control, manual and so on.
3. When the wind weak, the auto-start boost circuit, the real power by breeze to achieve.
4. Using PWM pulse charge mode, the battery of scientific management.
5. LED and LED display, the user can immediately look over the system operation status.
6. Over-charge, over discharge, overload, short circuit, reverse protection.
7. Automatic Identification 12V, 24Vbattery system.
Function description
1. The initial power Automatic Identification 12V/24V System, LED display 1 to show 12V system, display 2 to shows 24V system.
2. When the wind weak, fan output is insufficient to recharge the battery, the auto-start boost circuit.
3. When the wind is too strong, the unloading protection circuit automatically starts.
4. Working status LED instuctions
A. The battery indicator: Long bright when battery voltage is normal, flash slowly under-voltage, flash fast and load closed under over discharge.
B. Charging indicator light: Long-light when charging voltage, slow flash when start charging, flash fast and charging circuit closed when under overpressure.
C. Load inidicator: Long-light when load under normal working; slowly flash under over current, fast flash under protection (When the current exceeds 1.25 times the rated current for 30 seconds or 1.5 times for 5 seconds, close load; the immediate closure of the load when the load short-circuit.)
5. Working mode
A. Light control:When there is no sunlight ,the solar battery without voltage ,delay 3
Minutes ,to open load after confirmed, when there is sunlight,delay 3 minutes ,to close load after confirmed.
B. Light control plus time control: Start as the same as light control ,automatically shut down the load when the load to work to set time .
C. manual mode ::
User use keys to control the load on ,off
D. Debug mode Close the load when there is charging voltage,open the load when there is no charge voltage.
E. Normally open mode :Load remains open.
Note :A , model effected under the use of solar batteries.
6. Setting Method
Button function select switch for 3 seconds or more ,enter the adjustment mode ,digital tube flashing, release the button,Every time pressing the button will change a character ,Users can set working mode according to mode set table ,completesetting after digital tube stop flashing or re-press key more than 3 secongs.
Working mode set table
Digital tube display | Working mode | Digital tube display | Working mode |
0 | Light,control | 9 | Light,time control for 9 hours |
1 | Light,time control for 1 hours | A | Light,time control for 10 hours |
2 | Light,time control for 2hours | b | Light,time control for 11 hours |
3 | Light,time control for 3 hours | c | Light,time control for 12 hours |
4 | Light,time control for 4 hours | d | Light,time control for 13 hours |
5 | Light,time control for 5hours | E | Light,time control for 14 hours |
6 | Light,time control for 6hours | F | Manual mode |
7 | Light,time control for 7 hours | H | Debug mode |
8 | Light,time control for 8hours | L | Normally open mode |
Basic parameters
Item | WSC series |
Rated charge current | 10A 15A 20A |
Rated discharge current | 10A 15A 20A |
Battery | 12V 24V 12V24V AUTO |
Under voltage voltage | 11.5V;23v |
Over-discharge voltage | 10.5V;21V |
Overpressure protection | 22V;42V |
Charge back voltage | 13.2V;26.4V |
Over-discharge back voltage | 12V;24V |
Charge control | PWM Fuzzy Control |
Fan overpressure unloading voltage | ≥22V; ≥42V |
Protect circuit | Over-charge,over discharge,overload,short circuit,reverse |
Installation instruction
1. Wire preparation:Use cables which matching with current.
2. Connect Battery:Note that +,- polarity,do not anti-connect.Open power switch,the battery indicator will light at this time,digital tube will display the battery voltage system.
3. Connecting solar panels:Note that +,- polarity , do not anti-connect.
4. Connected wind generator:Connected to A,B,C terminal separately.
5. Connection load:Connected load to output port. Note that +, - polarity,do not anti-connect. Make sure there is no load short-circuit before connect,total current can not exceed rated current.
Connect battery first, then connect solar panels and wind generator.
Address:
No. 66 Temple Bay, Sunny Burg, Chenghuang Town, Nanjing, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company, Group Corporation
Business Range:
Health & Medicine
Company Introduction:
Cheer Solar group Limited is a big manufacturer of researching and producing solar controller, solar inverter, automotive inverter, solar panel, solar street lamp, solar battery and other alternative energy products.
It has more than 40 kinds of photovoltaic products which have been exported to more than 50 countries for their high technology, perfect design, excellent quality and top service, and the markets is covering Asia, Europe, Africa, Australia and so on. The company has many femous researchers and strong production capacity with 600000 units per year, which can satisfy the requirement of all customers. The technology has reached the peak of the national photovoltaic products.