Product Description
1. Foreword
The pressure transmitter uses a high-performance pressure-sensitive chip that combines advanced circuit processing and temperature compensation techniques to convert pressure changes into linear current or voltage signals. The product is small in size, easy to install, and is insulated by a stainless steel case. It is suitable for measuring gas and liquid media compatible with the material of the contact part. It can be used to measure gauge pressure, negative pressure and absolute pressure.
The hygienic (flush film) pressure transmitter is formed on the basis of the prototype of the universal pressure transmitter and is equipped with a welded sealing diaphragm structure. Its welded sealing isolating diaphragm device has a variety of different process connection structures, which are especially suitable for pressure measurement in high temperature, high viscosity, crystalline medium and easy to block, and also suitable for pressure measurement in sanitary and medical applications.
2. Application
Suitable for measurement of industrial process process control pressure. It is widely used in water industry, oil refinery, sewage treatment plant, building materials, light industry, machinery and other industrial fields to achieve measurement of liquid, gas and steam pressure.
3. Features
Reverse polarity protection and transient over current and over voltage protection, in line with EMI protection requirements;
Using laser to adjust the temperature compensation process, the measurement accuracy is higher and more stable;
Automatic temperature compensation, automatic temperature correction;
Anti-vibration, anti-shock, anti-radio frequency electromagnetic interference;
Strong overload and anti-interference ability, economical and practical;
Optional display module.
4.Technical Parameters
Measuring range | -0.1~+100Mpa(Optional) |
measurement accuracy | 0.2%FS,0.5%FS(default) |
output signal | 4-20mA,0-5V,0-10V |
Overload capability | <1.5Multiple range |
Temperature drift temperature drift | 0.03%FS/ºC |
Power supply | 12-36VDC (24V) |
Medium temperature | -40~75ºC -40~150ºC(High temperature type) |
Ambient temperature | -40ºC-80ºC |
Measuring medium | Gas and liquid that are non-corrosive to the stainless steel |
Protection level | IP65 |
load capacity | Current type with load capacity: ≤500Ω (without display) ≤250Ω (with display) |
Voltage output resistance:≤510Ω |
5. Precautions
Our products are equipped with instructions for use and certificates of conformity. There are technical parameters, please check carefully to avoid mistakes.
When installing, check whether the field interface is consistent with the product interface according to the product connection method and thread type. When connecting, it should be tightened slowly. The torque cannot be directly applied to the transmitter housing. It can only be added to the pressure interface. On the six parties. Ensure that the transmitter is mounted perpendicular to the ground. Use a wrench to tighten the transmitter from the hexagonal nut at the bottom of the transmitter during installation to avoid direct rotation of the transmitter.
When connecting the power supply, please follow the wiring instructions of our company.
This product is a precision instrument. It is forbidden to disassemble at will, prevent collision and fall. It is strictly forbidden to touch the sensor diaphragm with a sharp object, thus causing damage to the core.
The transmitter can be used after power-on. After preheating for 30 minutes, the output is more stable. If abnormality is found during use, turn off the power, stop using it, check it, or contact our technical department directly.
During the pressure measurement process, slowly pressurize and depressurize, avoid adding to high pressure or reduce to low pressure instantaneously. If measuring the pressure with faster change speed, add pressure to the connection outlet of the transmitter and the measured medium. Buffer device.
The human factors caused by pressure overload, wiring error, sensor diaphragm damage, etc. are not covered by the warranty..
Address:
Shun Tai Plaza, High - Tech Development Zone, Licheng District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Other
Business Range:
Industrial Equipment & Components
Management System Certification:
ISO 9001
Company Introduction:
Shangdong Renke Control Technology Co., Ltd. Is a leading environmental monitoring high technology enterprise in China. Renke is engaged in industrial sensor, communication gateway, industrial data platform, cloud computing service, and measurement control technology solution. We have won good reputation for high quality products and sincere service. Renke insists on the policy that"technology first, exquisite design, customer satisfied" we are careful with every detail. Every drawing has to be considered and revised repeatedly. Every products is the thought of designer.