Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EE;
Brand: Vouchinvan;
Winding Material: Copper/Aluminum;
Core Material: Silicon Steel Sheet;
Capacity: 30kVA-2500kVA;
Connection Type: Dyn11;
Frequecy: 50Hz/60Hz;
Impedance: 4%-6%;
Tapping Range: -/+5% or -/+ 2.5%;
No-Load Loss: 13~2590W;
Load Loss: 640~15400W;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou Electric;
High Voltage: 11kv 6kv 6.6kv 15kv 20kv 30kv;
Low Voltagewinding: 0.4kv 0.415kv;
Frequency: 50Hz/60Hz;
Rated Capacity: 50-31500 kVA;
Connection Group: Dyn11;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
Ambient Temperature: -40ºC -+ 40ºC;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio, Wind Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Cooling: Liquid/Oil Immersion;
Rated Capacity: 30kVA-31500kVA;
High Voltage: 6kv 6.6kv 10kv 11kv 12kv 20kv 33kv 35kv;
Winding Material: Copper;
|
Rated Capacity: 50-31500 kVA;
H.V. Winding: 22kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
High Voltage: 11kv;
Low Voltagewinding: 0.4kv 0.415kv;
Frequency: 50Hz/60Hz;
Rated Capacity: 50-31500 kVA;
Connection Group: Dyn11;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
Ambient Temperature: -40ºC -+ 40ºC;
|