Ovulation is the release ofa mature egg from the ovary. It signals the beginning of your fertile period. After the egg is released, the empty follicle on the ovary is converted to a structure known as the corpus luteum. It then begins to secrete progesterone. Progesterone is a hormone needed to ...

Learn More

Digital Fertility Testing System Comparison
Transaction Info
Price Negotiable US $ 200.00-550.00/ Piece US $ 3,400.00-3,700.00/ Piece US $ 3,680.00-3,700.00/ Piece US $ 3,680.00-3,700.00/ Piece
Min Order 200 Pieces 1 Pieces 1 Pieces 1 Pieces 1 Pieces
Payment Terms L/C, T/T L/C, T/T L/C, T/T L/C, T/T L/C, T/T
Quality Control
Product Certification CE, FDA, ISO13485 - - - CE, ISO13485
Management System Certification ISO 9001, ISO 13485 ISO 9001, ISO 9000, ISO 14000 ISO 9001, ISO 9000, ISO 14000 ISO 9001, ISO 9000, ISO 14000 ISO 9001, ISO 9000, ISO 14000
Trade Capacity
Export Markets - North America, South America, Eastern Europe North America, South America, Eastern Europe North America, South America, Eastern Europe North America, South America, Eastern Europe
Annual Export Revenue US$10 Million - US$50 Million US$50 Million - US$100 Million US$50 Million - US$100 Million US$50 Million - US$100 Million US$50 Million - US$100 Million
Business Model - Own Brand(BIOBASE) Own Brand(BIOBASE) Own Brand(BIOBASE) Own Brand(BIOBASE)
Average Lead Time - Off Season Lead Time: 3-6 months
Peak Season Lead Time: 3-6 months
Off Season Lead Time: 3-6 months
Peak Season Lead Time: 3-6 months
Off Season Lead Time: 3-6 months
Peak Season Lead Time: 3-6 months
Off Season Lead Time: 3-6 months
Peak Season Lead Time: 3-6 months
Product Attributes
Specification
Classification: Biological Diagnostics;
Type: Urine Analyzer;
Group: Female;
Classification: Pathology Lab;
Type: Slide Dryer (Hot Plate);
Group: All;
Application: Erythrocyte Sedimentation Rate Analysis;
Measurement Method: Infrared Detection;
Analysis Result: Westergren ESR Value (mm/Hour);
Throughput: Maximum 80 Tests/Hour;
Analysis Channels: 40 (Load up to 40 Samples for Analysis at The Same;
Loading Type: Load Samples at Any Time, Measure at Any Time;
Analysis Time: 30 Minutes or 60 Minutes Selectable;
Sampling Interval: 3 Min;
Measurement Range: 0~120mm/H;
Temperature Compensation: The Result Is Automatically Corrected to The Resul;
Result Resolution: 1mm/1h and 1mm/2h;
Blood Level Range: 50mm~64mm;
Result Precision: CV≤2%;
Channel Error: ≤±4mm/H;
Reading Accuracy: 0.2mm;
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor Extraction System;
Group: All;
Product Name: Nucleic Acid Extraction System;
Sample Quantity: 48;
Processing Volume: 20μl-1000μl;
Sample Volume: 20-500μl;
Sample Throughput: 1-32;
Magnetic Bead Recovery: >98%;
Extracting The Difference Between Holes: CV≤3%;
Heating Temperature: 8 Independent Heating Modules, Customize Lysis and;
Oscillating Mixing: Low,Medium and High Third Gears Are Adjustable, an;
Reagent Type: Magnetic Bead Open Platform;
Extraction Time: 15-40 Min/Round (Depending on The Reagent Used);
Internal Program: Be Able to Store >100 Groups of Programs;
Program Management: Powerful Program Editing Capabilities to Meet Diff;
Safety Door Design: After The Safety Door Is Opened,The Program Operat;
Built-in Air Duct: Yes;
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor Extraction System;
Group: All;
Product Name: Nucleic Acid Extraction System;
Nucleic Acid Extraction Method: Paramagnetic Particle Method;
Sample Volume: 20-1000UL;
Sample Capacity: 96-Well;
Extraction Time: 15min-60min;
Magnetic Bead Recovery: ≥98%;
Operating Temperature: Rt-105ºC;
Shock Function: Yes;
Temperature Accuracy: 0.1ºC;
Sample Protection Function: Power on Self-Check, Power off Protection, High-Te;
Disinfection Method: UV Light;
Safety Door Design: The Instrument Is Suspended When The Safety Door I;
Operating System: Windows System;
Scanning: Optional;
Storage: >1000;
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor Extraction System;
Group: All;
Product Name: Nucleic Acid Extraction System;
Sample Capacity Screen: 10.1 Inch Touch;
Sample Volume: 20-1000;
Sample Capacity: 1-96;
Magnetic Bead Recovery: ≥98%;
Extraction Time: 15- 40 Minutes;
Extracting The Differece Between Holes: CV≤3%;
Consumption: 500W;
Operating Temperature: Rt-120 ºC;
Product Purity A260/A280: DNA≥1.7-2.0; Rna≥1.8-2.1;
Shock Mlixing: Adjustable Speed (1-3);
Reagent Type: Open System for Magnetic Bead Method;
Power Supply: AC100V-240V 50Hz/60Hz;
External Size(W*D"H): 770*530"540mm;
Gross Weight: 95kg;
Supplier Name

Xinjiang Likang Xiangyun Biotechnology Co.,Ltd.

Diamond Member Audited Supplier

Biobase Biozone Co., Ltd.

Diamond Member Audited Supplier

Biobase Biozone Co., Ltd.

Diamond Member Audited Supplier

Biobase Biozone Co., Ltd.

Diamond Member Audited Supplier

Biobase Biozone Co., Ltd.

Diamond Member Audited Supplier