Specification |
After-sales Service: Life Service;
Warranty: 1 Year;
Appliance: Trace Impurity Analysis;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Three;
Detector: FID;
Energy Resolution: ≤7.5%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~20cm;
Chromatographic Column Diameter: 0.2~0.5mm;
|
Appliance: for Testing Dissolved Gas in The Oil;
Ray Type: X-Ray Spectrometer;
Gaspath System: Double;
Detector: Tcd, Double Fid and Methane Conversion Oven;
Energy Resolution: 0.5;
Chromatography Type: Gas Chromatography;
Application Standard: Complies to GB7252-2001, and ASTM D2887.;
Temperature Control Precision: +- 0.1 Deg C;
Gas Analyzing: H2, O2, N2, CH4, C2h2, C2h4, C2h6, Co, CO2;
Power Supply: 220V, 50Hz;
Environmental Condition: 5 ~ 35 Degree C;
Relative Humidity: Less Than 80%;
Condition: 100% Brand New;
Power Consumption: 2.5 ~ 3kw;
Warranty: 1 Year;
After-Sales Services Provided: Field Installation, Commision, Training;
|
After-sales Service: Online Technical Service;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: X-Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Specific: Pump+Detector+Injector+Colume;
|
Appliance: The Analysis of Environmental Samples;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Semi Preparative Column;
Chromatographic Column Length: 10~20cm;
Manual Injector: Rheodyne 7325I;
Working Station Software: Ws-100;
Chromatographic Column: 10mm;
|
After-sales Service: International Warranty;
Warranty: Two Years;
Appliance: The Analysis of Environmental Samples;
Ray Type: γ-Ray Spectrometer;
Gaspath System: Edxrf;
Detector: Sdd Detector;
Energy Resolution: 135EV;
Spectrometer Detector: SDD;
Stationary Phase: Edxrf;
Mobile Phase: Edxrf;
Chromatography Type: Edxrf;
Chromatographic Column Type: Edxrf;
Chromatographic Column Length: Edxrf;
Chromatographic Column Diameter: Edxrf;
Tube: Mini X-ray Tube From America;
Testing Time: 5-20s;
Sample Types: Solid, Liquid and Powders;
Certificate: CE, ISO;
|