Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Place of Origin: Zhejiang, China;
Brand Name: Aoasis;
Model Number: Aond-125;
Product Name: DC MCB;
Pole: 1p 2p 3p 4p;
Rated Current: 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125A;
Rated Voltage: DC250V, DC500V, DC750V, DC1000V;
Mechanical Life: 20000 Times;
Ambient Temperature: -35ºC~ +70ºC;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-2, GB14048.2;
Rated curret (In): 6A,10A,16A,20A,25A,32A,40A,50A,63A;
Trip curve: B, C, D;
Pole: 3P;
Rate voltage (Ue): 250VDC 500VDC 750VDC 1000VDC;
Insulation voltage(Ui): 500V (1P, 2P); 1000V(3P, 4P);
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 6kA;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection;
Product: Solar DC Circuit Breaker MCB;
Voltage: 550VDC;
Current: 80A 100A 125A;
Rated Breaking Capacity: 10ka;
Standard: IEC/En60947-2;
Certificate: CE/ISO9001/IEC/SAA;
Material: Fireproof Material;
Mechanical Life: 10000 Times;
Quality Assurance: Two Years;
Sample: Available;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection;
Product: Solar DC Circuit Breaker MCB;
Voltage: 550VDC;
Current: 80A 100A 125A;
Rated Breaking Capacity: 10ka;
Standard: IEC/En60947-2;
Certificate: CE/ISO9001/IEC/SAA;
Material: Fireproof Material;
Mechanical Life: 10000 Times;
Quality Assurance: Two Years;
Sample: Available;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection;
Product: Solar DC Circuit Breaker MCB;
Voltage: 250VDC;
Current: 80A 100A 125A;
Rated Breaking Capacity: 10ka;
Standard: IEC/En60947-2;
Certificate: CE/ISO9001/IEC/SAA;
Material: Fireproof Material;
Mechanical Life: 10000 Times;
Quality Assurance: Two Years;
Sample: Available;
|