Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Installation: DIN Rail;
Structure: RCCB;
Poles Number: 3p+N;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB, Short-Circuit Protection;
Name: Residual Current Circuit Breaker RCCB;
Pole: 1p+N 2p 3p 3p+N 4p;
Rated Current: 6A 10A 16A 20A 25A 32A 40A 50A 63A;
Rated Voltage: 230/400V;
Insulation Voltage Ui: 500V;
Certificate: CE/ISO9001/CCC;
Mechanical Life: 20000 Times;
Rated Short-Circuit Breaking Capacity: 4.5ka, 6ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: ELCB;
Poles Number: 2p ,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Poles: 1p,2p, 3p+N,4p;
Frequency: 50/60Hz;
Rated Current in(a): 10,16, 20,25, 32,40, 63A;
Rated Residual Operating Current: 0.03,0.1,0.3A;
Rated Working Voltage Ue(V): 250/500V;
Breaking Capacity(a): 6ka;
Rated Limiting Short-Circuit Current: 10000A;
Mechanical Life(Times): 20000times;
Electric Life: 6000times;
Bcd Cure: C;
International Certification: CCC/CB;
Standard: IEC60898-1 GB/T 0963.1;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Product Name: MCCB(Molded Case Circuit Breaker);
Poles: 2p;
Frame Current(Inm): 100af;
Rated Current: 60A;
Rated Voltage(Ue): AC 660V;
Rated Frequency: 50/60 Hz;
Break Capacity: 25ka at 220/240VAC;
Rated Insulation Voltage Ui(V): 690V;
Rated Impulse Withstand Voltage Uimp(Kv): 6kv;
Color: Grey/ White;
Standard: IEC60947-2/GB14048.2;
Material: High Quality Bakelite, Silver, Copper;
Mechanical Life: 12000 Times;
Certificate: CE, Ks, CCC, ISO9001;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCCB;
Poles Number: 2p ,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Poles: 2pole, 4pole;
Frequency: 50/60Hz;
Rated Current in(a): 16, 20,25, 32,40, 50,63A;
Rated Residual Operating Current: 0.03,0.1,0.3A;
Rated Working Voltage Ue(V): 230/400V;
Breaking Capacity(a): 4.5ka;
Limiting Value of Un-Operating Current: 6in;
Rated Limiting Short-Circuit Current: 10000A;
Mechanical Life(Times): 20000times;
Electric Life: 4000times;
Bcd Curve: C;
|