Specification |
Model: Aw-Cbl2166-6;
Diameter: 6″(150mm);
Working Voltage: 20VDC to 28VDC;
Work Current @24VDC: ≤60mA;
Volume (dB) @1m: ≥90dB;
Dimensions: 150mm*150mm*60mm;
|
Type: Infrared Beam Smoke Detector;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Infrared Beam Smoke Style;
Infrared Sensor Installation: Wall Mounted;
Product Name: Flame Proof Beam Smoke Detector Industrial;
Operating Voltage: 24VDC;
Standby Current: ≤10mA;
Alarm Current: ≤25mA;
Indicator: Red, Green, Yellow LED;
Detection Distance: 3-100m;
Detector Protective Diameter: 14m;
Protected Area: Ideal Maximum Is 100X14m;
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 197X195X116mm;
Operating Temperature: -15ºC- +50ºC;
Operating Humidity: ≤95% Rh;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|
Type: Infrared Beam Smoke Detector;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Infrared Beam Smoke Style;
Infrared Sensor Installation: Wall Mounted;
Product Name: Beam Smoke Detector;
Operating Voltage: 24VDC;
Standby Current: ≤10mA;
Alarm Current: ≤25mA;
Indicator: Red, Green, Yellow LED;
Detection Distance: 3-100m;
Detector Protective Diameter: 14m;
Protected Area: Ideal Maximum Is 100X14m;
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 197X195X116mm;
Operating Temperature: -15ºC- +50ºC;
Operating Humidity: ≤95% Rh;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|
Type: Smoke Detectors;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Explosion Proof Smoke Detector;
Operating Voltage: 24VDC;
Standby Current: ≤120μa;
Alarm Current: 10mA≤I≤30mA;
Indicator: Red LED;
Power-on Time: ≤10s;
Atmospheric Pressure: 80~110kpa;
The Highest Wind Speed: 7.6m/S (1500FPM);
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 100mm X 150mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|
Type: Smoke Detectors;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Explosion Proof Smoke Detector;
Operating Voltage: 24VDC;
Standby Current: ≤120μa;
Alarm Current: 10mA≤I≤30mA;
Indicator: Red LED;
Power-on Time: ≤10s;
Atmospheric Pressure: 80~110kpa;
The Highest Wind Speed: 7.6m/S (1500FPM);
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 100mm X 150mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|