About this Item
Details
Company Profile

Price

Min. Order Reference FOB Price

1 Piece US$510.00-515.00 / Piece

Sepcifications

  • Type Fire Alarm Host
  • Function Networked
  • Usage Fire, Smoke
  • Certification CE, ISO, CCC, Lpcb
  • Alarm Volume (within 1m) ≥80dB
  • Networking Mode RS485 & Can
  • Wiring Mode Bus System
  • Transport Package Carton
  • Specification 430× 560× 170mm
  • Trademark Asewnare
  • Origin China
  • Mains Supply 230VAC
  • Mains Fuse T3.15al250V
  • Power Rating Imax.a=1.2A; Imax.B=2.6A; Imin=0.65A
  • Max. Charging Current 1.2A
  • Max. Battery Supply Current 4A
  • Max. Internal Resistance of Battery 1.5Ω
  • Battery Fuse F8al250V
  • Recommended Battery Cable 14AWG
  • Quiescent Current (Full Loaded) < 0.4A
  • Max. Output Current 0.5A

Product Description

LPCB Approved fire fighting system 32 zone control panel Introduction: The purpose of the AW-FP300Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 with qualities of simple ...

Learn More

Addressable Fire Alarm Comparison
Transaction Info
Price US $ 510.00-515.00/ Piece US $ 1/ Piece US $ 1/ Piece US $ 1/ Piece US $ 1/ Piece
Min Order 1 Pieces 1 Pieces 1 Pieces 1 Pieces 1 Pieces
Payment Terms L/C, T/T, Western Union, cash L/C, T/T, D/P L/C, T/T, D/P, Western Union, Paypal L/C, T/T, D/P, Western Union, Paypal L/C, T/T, D/P, Western Union, Paypal
Quality Control
Product Certification CE, ISO, CCC, Lpcb CE, UL, En CE, UL, En En En
Management System Certification ISO 9001 ISO 9001 ISO 9001 ISO 9001 ISO 9001
Trade Capacity
Export Markets North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East
Annual Export Revenue US$10 Million - US$50 Million US$5 Million - US$10 Million US$5 Million - US$10 Million US$5 Million - US$10 Million US$5 Million - US$10 Million
Business Model OEM, ODM, Own Brand(Asenware) OEM, ODM, Own Brand(Numens) OEM, ODM, Own Brand(Numens) OEM, ODM, Own Brand(Numens) OEM, ODM, Own Brand(Numens)
Average Lead Time Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Product Attributes
Specification
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: RS485 & Can;
Wiring Mode: Bus System;
Mains Supply: 230VAC;
Mains Fuse: T3.15al250V;
Power Rating: Imax.a=1.2A; Imax.B=2.6A; Imin=0.65A;
Max. Charging Current: 1.2A;
Max. Battery Supply Current: 4A;
Max. Internal Resistance of Battery: 1.5&Omega;;
Battery Fuse: F8al250V;
Recommended Battery Cable: 14AWG;
Quiescent Current (Full Loaded): < 0.4A;
Max. Output Current: 0.5A;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Addressable Loops: 1 or 2;
Number of Connected Devices Per Loop: 125;
Loop Current(Max): 400 Ma;
Programmable Sounder Groups(Max): 512;
Number of Networked Panels: 4;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Wiring Mode: Sub-Line System;
Alarm Zone Circuits: 2,4 or 8;
Number of Connected Devices Per Zone: 32;
Number of Programmable Output Relays: 2;
Ancillary Fire C/O Relay: 2;
Ancillary Fault N/C Relay: 1;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Wiring Mode: Sub-Line System;
Alarm Zone Circuits: 2,4 or 8;
Number of Connected Devices Per Zone: 32;
Number of Programmable Output Relays: 2;
Ancillary Fire C/O Relay: 2;
Ancillary Fault N/C Relay: 1;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Wiring Mode: Sub-Line System;
Alarm Zone Circuits: 2,4,8,16;
Number of Connected Devices Per Zone: 32;
Standby Battery Capacity (2xdc 12V): 7.2ah;
Number of Programmable Output Relays: 2;
Ancillary Fire C/O Relay: 2;
Ancillary Fault N/C Relay: 1;
Number of Networked Panels: 4;
Supplier Name

Shenzhen Asenware Test and Control Technology Co., Ltd.

Diamond Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier