Specification |
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤8%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Model: Bk-Lci5100;
Type: Isocratic Pump;
Flow Rate Range: 0.001-10.000ml/Min, in;
Flow Accuracy: ≤±0.2% (1.00ml/Min, H2O,R.T.,8.5MPa);
Flow Precision: Rsd≤0.06% (1.00ml/Min, H2O,R.T.,8.5MPa);
Maximum Pressure: 63MPa;
Pressure Accuracy: ≤±3.0%;
Pressure Pulsation: ≤0.1MPa;
Wavelength Range: 190-800nm;
Wavelength Repeatability: ≤0.1nm;
Wavelength Accuracy: ≤±1.0nm;
Band Width: 6nm;
Response Time: 0.0s-5s;
Baseline Noise: ≤±0.25×10-5au(Empty Cell254nm, 1.;
Drift: ≤0.5×10-4au/H(Empty Cell,, 60min);
|
Warranty: 1 Year;
Appliance: for Testing Dissolved Gas in The Oil;
Ray Type: X-Ray Spectrometer;
Gaspath System: Double;
Detector: Tcd, Double Fid and Methane Conversion Oven;
Energy Resolution: 0.5;
Chromatography Type: Gas Chromatography;
Application Standard: Complies to GB7252-2001, and ASTM D2887.;
Temperature: Room Temperature Above 8 Degree~ 450degree;
Temperature Control Precision: +- 0.1 Deg C;
Gas Analyzing: H2, O2, N2, CH4, C2h2, C2h4, C2h6, Co, CO2;
Power Supply: 220V, 50Hz;
Environmental Condition: 5 ~ 35 Degree C;
Relative Humidity: Less Than 80%;
Condition: 100% Brand New;
Power Consumption: 2.5 ~ 3kw;
After-Sales Services Provided: Field Installation, Commision, Training;
Weight: 78 Kgs;
Operating Display: 5.7 Inch Color LCD DOT Matrix English Version;
Temperature-Programmed Order: 16 Order;
Start Sampling: Manual, Automatic Optional;
|
After-sales Service: Online Technical Support;
Warranty: 1 Year;
Appliance: Medicine and Health, Petrochemical, Environmental;
Ray Type: /;
Gaspath System: /;
Detector: /;
Energy Resolution: /;
Spectrometer Detector: /;
Stationary Phase: /;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: /;
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Product Name: Gas Chromatograph;
Model: Bk-Gc112A;
Capacity: 22L;
Temp. Range: Rt+5ºC~400ºC;
Temp.Accuracy: ±0.1ºC;
Temp.Program: 9 Step;
Program Total Time: 9999.9 Min;
Maxtemp. Heating Rate: 60ºC/Min;
Pre Column Pressure Range: 0-400kpa;
Pre Column Pressure Accuracy: 0.1kpa;
Power Supply: AC220V±10%, 50Hz;
Standard Accessory: Fid Detector,Capillary Injection System, Chromat;
Optional Accessory: Tcd Detector, Chromatographic Column, Gas Purifier;
Package Size (W*D*H): 740*730*840mm;
Gross Weight: 80 Kg;
|
After-sales Service: Online After Sales Service;
Warranty: 1 Year;
Appliance: Medical Research;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: SPL;
Energy Resolution: ≤7.5%;
Spectrometer Detector: Si(Li);
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Semi Preparative Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Model: Bk-Gc112A;
Temp. Range: Rt~450ºC;
Temp. Accuracy: ≤±0.1ºC;
Temp. Program: 16-Phase;
Max. Temp. Heating Rate: 40ºC/Min;
Detection Limit: ≤3×10-12g/S (Sample:N-Hexadecane);
Baseline Drift: ≤1X10-13A/30min;
Standard Accessory: Fid Detector, Chromatography Workstation Software;
|
After-sales Service: 1year;
Warranty: 1year;
Appliance: Trace Impurity Analysis;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: Si(Li);
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1year;
Wavelength Range: 325-1000nm;
Band Width: 2nm;
Light Source: Imported Tungsten Lamp;
Power: 120W;
|