Specification |
Classification: Biological Diagnostics;
Type: Elisa Washer Bk-9622;
Group: /;
Model: Bk-9622;
Cleaning Head: 8 Channels and 12 Channels;
Microplate Types: Four Kinds, Flat Bottom, U Bottom, V Bottom, Round;
Average Residue: <1μl(Per Hole);
Liquid Suction Time: 0.1~999.9 Seconds Adjustable, with an Interval of;
Line Flush Time: 1~999 Seconds, Adjustable;
Washing Programs: up to 200 Programs;
Display: 7-Inch Touch Display;
|
Classification: Biological Diagnostics;
Type: Elisa Microplate Washer;
Group: All;
Product Name: Elisa Microplate Washer;
Model: Bk-9622;
Microplate Types: Applicable to All Types of Microplates. Flat Botto;
Washingmode: 2 Kinds Ofautomatic Washing,Soaking Andshaking, to;
Average Residue: <1μl;
Number Ofmicroplate: 1- 12 Rows Adjustable;
Cleaninghead: 8 Channels and 12 Channels;
Liquidsuctiontime: 0.1-9.9 Seconds Adjustable, with an Interval of 0;
Washingprograms: up to 100 Programs;
Flushingpipeline Time: 0-240 Seconds Adjustable;
Display: 5.0 Inch LCD Screen;
Liquidinjectionchannels: 3 (2 Types of Lotion and 1 Type of Distilled Water;
Cleaningneedleposition: 5 Types Adjustable (Horizontal,Left,Center,Right,;
Packing Size(W*D*H): 710*510*451mm;
Gross Weight: 23kg;
|
Classification: Biological Diagnostics;
Type: Semi-Auto Biochemistry Analyzer;
Group: All;
Product Name: Semi-Auto Biochemistry Analyzer;
Gross Weight: 19kg;
External Size (W*D*H): 340*380*180mm;
Power Supply: AC110/220V±10% 60/50Hz;
Interface: RS-232, USB;
Printer: Built-in Thermal Printer;
Display/Keyboard: Touch Screen;
Incubator Temperature Control: Rt+25ºC, 30ºC, 37ºC;
Incubating Positions: 20 Incubation Positions;
Reading Cuvette: Both Through Cell and Direct Reading Cuvette;
Photometric System: Light Source: 6V, 10W Halogen Lamp;
Measuring System: Measuring Range: 0~2.500 Od;
|
Classification: Biological Diagnostics;
Type: Chemiluminescence Immunoassay System;
Group: All;
Throughput: 80t/H;
Principle: Magnetic Particle Enzymatic Chemiluminescence;
Modes of Operation: Random, Batch and Stat;
Separation Method: Magnetic Separation Technology;
Sample Positions: 60;
Reagent Positions: 30 PCS;
Incubation Positions: 50;
Time to 1st Result: 18 Minutes;
|
Classification: Biological Diagnostics;
Type: Urine Analyzer;
Group: All;
Product Name: Urine Analyzer;
Gross Weight: 8kg;
Power Supply: AC220±10%, 50/60Hz, 110±10%,60Hz;
Fuse Specification: 250V,2A;
Working Environment: Temperature:15~35ºC; Humidity:≤75%.;
Printe: Built-in Thermal Printer;
Language: English and Spanish. Other Languages on Request;
Interface: RS-232;
Storage: 20000 Results;
Wavelength: 525nm, 610nm, 660nm;
Sampling Volume: <1.0ml;
Sample Volume: Not Lower Than The Marked Scale Line on The Test T;
Sample Racks: 5 Test Tube Racks(5*10 Samples);
Test Speed: 240tests/Hour;
Assay Method: Albedometry;
|