Specification |
Application: Power, Electronic, Rectifier;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: Ring;
Tapping Range: ±2X2.5%;
Vector Group: Dyn11, Yyn0;
High Voltage: 10kv;
Low Voltage: 0.4kv;
Rated Capacity: 400kVA;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Transformer Type: Cast Resin Dry Type Transformer;
Rated Capacity: 3000kVA or Customized;
Rated Voltage(Hv/LV): 33/0.44kV;
Frequency: 50 Hz;
Impedance: 4~6%;
Tapping Range: +2X2.5%/-2X2.5%;
Cooling Way: AN/AF;
Vector Group: Dyn11;
Winding Material: Copper;
Core Materials: Silicon Steel;
Insulation Level: as Per IEC Standard;
Temperature Rise: Customized;
Accessories: Fans, Enclosure;
Optional Protective Enclosure: IP00/IP20/IP23/Cutomized;
Applied Standards: GB/T10228, GB1094.11, IEC60076-11, DIN42523;
|
Application: Power;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Rated H.V.: 34.5/13.2/13.8/12.47/14.4/15/7.62/7.2kv;
Rated L.V.: 120/240/480/347/600V;
Frequency: 60Hz;
Winding Material: Copper/Aluminium;
Vector Group: II0/II6;
Applied Standard: IEC60076/IEEE/ANSI/DOE;
|
Application: Power;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Rated H.V.: 34.5/13.2/13.8/12.47/14.4/15/7.62/7.2kv;
Rated L.V.: 120/240/480/347/600V;
Frequency: 60Hz;
Winding Material: Copper/Aluminium;
Vector Group: II0/II6;
Applied Standard: IEC60076/IEEE/ANSI/DOE;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 125kVA;
High Voltage: 10/11kV;
Low Voltage: 0.4kV;
Impedance Voltage: 4%;
No-Load Loss: 0.47kW;
Load Loss: 1.85kW;
No-Load Current: 0.7%;
Frequency: 50/60Hz;
Connection Group: Yyn0/Dyn11;
Insulation Class: F;
|