Specification |
Type: 10kv/12kv/15kv;
Structure: According to Customer Requirements;
Installation: Outdoor High-voltage;
Operation: Manual/Electric/Pneumatic/Hydraulic;
Grounding Mode: According to Customer Requirements;
Movement Mode: According to Customer Requirements;
Number of Poles: According to Customer Requirements;
Grounding: According to Customer Requirements;
Series: Two;
Run: According to Customer Requirements;
Switching Mode: According to Customer Requirements;
Common Model: Gw9;
Structure of Operating: According to Customer Requirements;
Brand: Chbeb;
Customizable: OEM/According to Customer Requirements;
|
Type: High-voltage;
Structure: Three-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Manual;
Grounding Mode: Not Grounding;
Movement Mode: Plug-in Type;
Number of Poles: Three Pole;
Grounding: Un Grounded;
Series: Three;
Run: Plug-In;
Switching Mode: Single Throw-in;
Common Model: /;
Structure of Operating: Manual;
Brand: /;
Rated Voltage: 10kv-24kv;
Rated Current: 30A-63A;
Tapping Position: 3-7;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Manual;
Grounding Mode: Not Grounding;
Movement Mode: Plug-in Type;
Number of Poles: 2-10 Pole;
Grounding: Single Ground;
Series: Four;
Run: Plug-In;
Switching Mode: Double-Throw Type;
Common Model: SR;
Structure of Operating: Electric;
Brand: Aswich;
Current: 6~55A;
Voltage Ui: 1000V/1500V;
Rated Impulse Withstand Voltage Uimp: 8000V;
Mounting Type: Box, DIN-Rail, Door Interlock, Panel/Hole Mounting;
Lock: Lockable;
IP Protection: IP66;
Mechanical Life: 10000cycles;
Standard: IEC60947-3, As60947.3;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Vertical Rotary Type;
Number of Poles: Three Pole;
Grounding: Single Ground;
Series: Three;
Run: Vertical Rotation;
Switching Mode: Single Throw-in;
Common Model: YR;
Structure of Operating: Electric;
Rated Insulation Voltage Ui: 1500V;
Rated Current: 13/20/25/40/50A;
Rated Thermal Current Ith: 32/40/55A;
Protection Level: IP66;
Rated Impulse Withstand Voltage Uimp: 8000V;
Rated Short-Time Withstand Current(1s): 780A;
Rated Short-Time Making Capacity: 1200A;
Pole: 2p, 4p;
Certificates: RoHS, CE, TUV, CB, SAA;
Ambient Temperature: -5°c ~+40°;
Pollution Degree: 3;
Rated Frequency: 50/60Hz;
Standard: IEC60947-3, As60947.3;
Arcing Time: 1ms;
Mounting Type: Plastic Enclosure Box, Aluminum Enclosure Box;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Vertical Rotary Type;
Number of Poles: Three Pole;
Grounding: Single Ground;
Series: Three;
Run: Vertical Rotation;
Switching Mode: Single Throw-in;
Common Model: YR;
Structure of Operating: Electric;
Brand: Aswich;
Rated Insulation Voltage Ui: 800V;
Rared Current: 16, 20, 25, 32, 40, 63, 80, 100,125A;
Pole: 2p, 3p, 4p, 6p,8p;
Certificates: CE, TUV;
IP Code: IP66;
Rated Impulse Withstand Voltage Uimp: 8kv;
Rated Conditional Short-Circuit Current: 1.5ka;
Rated Short-Time Making Capacity: 0.76ka, 1s;
Rated Short-Time Withstand Current: 20A, 35A, 63A;
Rated Insulation Voltage (Le): 50/60Hz;
Auxiliary Contacts Code: P1 1no+1nc, P2 2no;
Mechanical Endurance: 100000;
Ambient Temperature: Operating -25~+55ºC Storage-40~+70ºC;
Interrupting Medium: Air;
Pollution Degree: 3;
|