Specification |
|
Type: Emergency Ventilator;
Used for: Adult, Child, Infant;
Model Name: PA-700b Standard Ventilator;
Display: 10.4 Inch High Visibility Color TFT Displya;
Ventilation Mode: A/C, Ippv, Sippv, Imv, Simv, Standby, Spont, Manua;
Minute Volume: Greater Than or Equal to 18L;
Back up Power Supply: at Least 4 Hours;
Tidal Volume: Adjustable Range: 50~1500ml;
Output Oxygen Concentration: 40%~100%;
Respiratory Rate: 1~99bpm;
Inspiratory/Expiratory (I: E) Ratio: 4:1~1:4;
Peep: 0~10CMH2o;
Simv Rate: 1~20bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o;
Gas Supply Requirement: 280-600 Kpa Medical Grade Oxygen;
Adjustable Oxygen Concentration: 45~100%;
Pressure Limit: 1.0kpa~6.0kpa;
|
Type: Emergency Ventilator;
Used for: Adult, Child, Infant;
Model Name: PA-700b Advanced Ventilator;
Display: 10.4 Inch High Visibility Color TFT Displya;
Ventilation Mode: A/C, Ippv, Sippv, Imv, Simv, Standby, Spont, Manua;
Minute Volume: Greater Than or Equal to 18L;
Back up Power Supply: at Least 4 Hours;
Tidal Volume: Adjustable Range: 50~1500ml;
Output Oxygen Concentration: 40%~100%;
Respiratory Rate: 1~99bpm;
Inspiratory/Expiratory (I: E) Ratio: 4:1~1:4;
Peep: 0~10CMH2o;
Simv Rate: 1~20bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o;
Gas Supply Requirement: 280-600 Kpa Medical Grade Oxygen;
Adjustable Oxygen Concentration: 21~100%;
Pressure Limit: 1.0kpa~6.0kpa;
|
Type: Emergency Ventilator;
Used for: Adult, Child, Infant;
Model Name: PA-900b Advanced Ventilator;
Display: 10.4 Inch High Visibility Color TFT Display;
Ventilation Mode: Sippv, Ippv, Simv, Psimv, Psv, CPAP, Pcv;
Minute Volume: Greater Than or Equal to 18L;
Back up Power Supply: at Least 4 Hours;
Tidal Volume: Adjustable Range: 20~1500ml;
Respiratory Rate: 1~99bpm;
Inspiratory/Expiratory (I: E) Ratio: 4:1~1:4;
Peep: 0~10CMH2o;
Simv Rate: 1~20bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o;
Gas Supply Requirement: 280 - 600 Kpa Medical Grade Oxygen;
Oxygen Concentration Alarm: Upper Limit: 22~100%, Lower Limit: 21~80%;
Pressure Limit: 1.0kpa~6.0kpa;
Trigger Sensitivity (Flow): 1~10L/M;
|
Type: Emergency Ventilator;
Used for: Adult, Child, Infant;
Model Name: PA-900b Standard Ventilator;
Display: 10.4 Inch High Visibility Color TFT Displya;
Ventilation Mode: Sippv, Ippv, Simv, Psimv, Psv, CPAP, Pcv;
Minute Volume: Greater Than or Equal to 18L;
Back up Power Supply: at Least 4 Hours;
Tidal Volume: Adjustable Range: 20~1500ml;
Respiratory Rate: 1~99bpm;
Inspiratory/Expiratory (I: E) Ratio: 4:1~1:4;
Peep: 0~10CMH2o;
Simv Rate: 1~20bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o;
Gas Supply Requirement: 280 - 600 Kpa Medical Grade Oxygen;
Oxygen Concentration Alarm: Upper Limit: 22~100%, Lower Limit: 21~80%;
Pressure Limit: 1.0kpa~6.0kpa;
Trigger Sensitivity (Flow): 1~10L/M;
|