Specification |
After-sales Service: Free Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Chromatograph;
Gaspath System: Double;
Detector: FID;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Pump Flow Rate Range: 0.001-9.999ml/Min;
Pump Flow Rate Accuracy: 0.5%(1ml/Min, Water, Room Temperature);
Pump Flow Rate Precision: Rsd Less Than 0.08%(1ml/Min, Water, Room;
Pump Pressure Range: Less Than 42MPa;
UV Detector Lamp: Deuterium Lamp;
UV Detector Wavelength Range: 190-700nm;
UV Detector Baseline Noise: Less Than 8*10-6au;
UV Detector Baseline Drift: Less Than 1*10-4au/H;
UV Detector Detection Limit: 4*10-9 G/Ml(Naphthalene/Methyl Alcohol Solvent);
UV Detector Wavelength Accuracy: 1nm;
|
After-sales Service: Online Training;
Warranty: 1 Year;
Appliance: Biochemistry;
Detector: FID;
Energy Resolution: ≤7%;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Name: Gas Chromatograph;
Model: Bk-Gc112A;
Capacity: 22L;
Temp. Range: Rt+5ºC~400ºC;
Temp.Accuracy: ±0.1ºC;
Temp.Program: 9 Step;
Program Total Time: 9999.9 Min;
Maxtemp. Heating Rate: 60ºC/Min;
Power Supply: AC220V±10%, 50Hz;
Standard Accessory: Fid Detector;
Package Size (W*D*H): 740*730*840mm;
Gross Weight: 80kg;
Hydrogen Flame Ionization Detector (Fid): Logarithmic Amplifier;
Flow Setting Range: H2: 0-200ml/Min;
Flow Setting Rangen2: 0-150ml/Min;
|
After-sales Service: Online Support;
Warranty: 1 Year;
Appliance: Medical Research;
Ray Type: /;
Gaspath System: /;
Detector: UV/Vis Detector;
Energy Resolution: /;
Spectrometer Detector: /;
Stationary Phase: /;
Mobile Phase: /;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: /;
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Model: Bk-Lci3100;
Quantity: 1 Set;
Flow Rate Range: 0.001ml/Min-10.000ml/Min;
Flow Accuracy: <+-0.2% (1.00ml/Min, H2O, R.T., 8.5MPa);
Flow Precision: Rsd≤0.075% (1.00ml/Min, H2O, R.T., 8.5MPa);
Maximum Pressure: 45MPa;
Pressure Accuracy: <+-3.0%;
Pressure Pulsation: <0.1MPa;
Wavelength Range: 190-700nm;
Wavelength Repeatability: <0.1nm;
Wavelength Accuracy: <+-1.0nm;
Band Width: 8nm;
Response Time: 0.0s-5s;
Baseline Noise: <+-0.5×10-5au;
Drift: <1.0×10-4au/H;
|
After-sales Service: Online Training;
Warranty: 1 Year;
Appliance: Biochemistry;
Detector: FID;
Energy Resolution: ≤7%;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Name: Gas Chromatograph;
Model: Bk-Gc7820;
Temp. Range: Rt~450ºC;
Temp. Accuracy: ≤±0.1ºC;
Temp. Program: 16-Phase;
Max. Temp. Heating Rate: 40ºC/Min;
Fiddetection Limit: ≤3×10-12g/S;
Baseline Drift: ≤1X10-13A/30min;
Linear Range: ≥107;
Sensitivity: >10000mv.Ml/Mg;
Power Supply: AC110/220V±10%, 50/60Hz;
Package Size (W*D*H): 800*570*650mm;
Gross Weight: 75kg;
Standard Accessory: Fid Detector;
Optional Accessory: Sample Injection System;
|
After-sales Service: Online Support;
Warranty: 1 Year;
Appliance: Medical Research;
Ray Type: /;
Gaspath System: /;
Detector: UV/Vis Detector;
Energy Resolution: /;
Spectrometer Detector: /;
Stationary Phase: /;
Mobile Phase: /;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: /;
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Model: Bk-Lci1100;
Double Plunger Reciprocating Pump: 1 Set;
Flow Range: 0.001ml/Min-10.000ml/Min;
Setting Step Size: 0.001ml/Min;
Flow Accuracy: ≤±0.3% (1.00ml/Min, H2O, R.T., 8.5MPa);
Flow Stability: Rsd≤0.1% (1.00ml/Min, H2O, R.T., 8.5MPa);
Maximum Pressure: 42MPa;
Display Pressure Error: <+-3.0%;
Pressure Fluctuation: <1.0%;
Power Dissipation: 80W;
Wavelength Range: 190-700nm;
Wavelength Repeatability: +-0.1nm;
Wavelength Accuracy: <+-1.0nm;
Spectrum Band Width: 8nm;
Response Time: 0.0s-4.9s;
|