Specification |
Application: Power, Electronic;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Power Transformer, Three Phase Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Honle;
Material: Copper Winding;
Type: Dry-Type Transformer;
Connection Group: Yyn0, Dyn11;
Rated Capacity: 30kVA-400kVA;
Short-Circuit Impedance: 4.0/6.0%;
Hv: 6-11kv;
High-Voltage Tapping Range: ±5%/ ±2*2.5%;
LV: 0.4kv;
|
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Frequency Characteristics: Low Frequency;
Connection Group: Yyn0, Dyn11, Dyn5 or Others;
Standards: GB1094-1996; Jb/T10088-2004; GB/T6451-2008; Eqv I;
Short Circuit Impedance: Standard Impedance (for Details See Technical Data;
Tapping Range: ± 2*2.5%;
Voltage Grade: 6kv, 10kv, 11kv, 13.8kv, 15kv;
Voltage Regukation Mode: off Circuit Tap Changing or on Load Tap Changing;
Frequency: 50Hz; 60Hz;
Type: Transformer;
|
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Frequency Characteristics: Low Frequency;
Connection Group: Yyn0, Dyn11, Dyn5 or Others;
Standards: GB1094-1996; Jb/T10088-2004; GB/T6451-2008; Eqv I;
Short Circuit Impedance: Standard Impedance (for Details See Technical Data;
Tapping Range: ± 2*2.5%;
Voltage Grade: 6kv, 10kv, 11kv, 13.8kv, 15kv;
Voltage Regukation Mode: off Circuit Tap Changing or on Load Tap Changing;
Frequency: 50Hz; 60Hz;
Type: Transformer;
|
Application: Power, Electronic;
Cooling Method: Oil-immersed Type Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Power Loss: No-Load Loss Is 30% Lower Saving Than Standard;
Material: Oil, CRGO, Copper;
Color: Standard Grey in Default;
High Voltage: 6 6.3 10 10.5 11;
Medium Voltage: ±5% or ±2×2.5%;
Low Voltage: 0.4;
Connection Symbol-1: 30-500kVA Is Dyn11 Yyn0 Yzn11;
Connection Symbol-2: Above 500kVA Is Dyn11 Yyn0;
Warranty: 12 Months;
Design Capacity: up to 200mva;
No-Load Loss Range: 12~67.7kw or Customized;
Load Loss: 47~270kw or Customized;
No-Load Current: 0.6~0.30% or Customized;
Tap-Changing: on-Load Tap-Changing or off-Load Tap-Changing;
Sound Level: 35~50dB Range;
|
Application: Power, Electronic;
Cooling Method: Oil-immersed Type Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Power Loss: No-Load Loss Is 30% Lower Saving Than Standard;
Material: Oil, CRGO, Copper;
Color: Standard Grey in Default;
High Voltage: 6 6.3 10 10.5 11;
Medium Voltage: ±5% or ±2×2.5%;
Low Voltage: 0.4;
Connection Symbol-1: 30-500kVA Is Dyn11 Yyn0 Yzn11;
Connection Symbol-2: Above 500kVA Is Dyn11 Yyn0;
Warranty: 12 Months;
Design Capacity: up to 200mva;
No-Load Loss Range: 12~67.7kw or Customized;
Load Loss: 47~270kw or Customized;
No-Load Current: 0.6~0.30% or Customized;
Tap-Changing: on-Load Tap-Changing or off-Load Tap-Changing;
Sound Level: 35~50dB Range;
|