Specification |
Type: High-voltage;
Structure: Three-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Not Grounding;
Movement Mode: Horizontal Rotary Type;
Number of Poles: Unipolar;
Grounding: Un Grounded;
Series: Two;
Run: Turn the Horizontal;
Switching Mode: Single Throw-in;
Common Model: Gw;
Structure of Operating: Electric;
Brand: Ville;
Test: Type Test Report;
Rated Voltage: 40.5kv;
Rated Current: 400 630A;
Rated Peak Withstand Current: 31.5 50ka;
Rated Short-Circuit Keeping Time: 2ms;
Rated Short-Time Withstand Current: 12.5 20ka;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Indoor High-voltage;
Operation: Manual;
Grounding Mode: Not Grounding;
Movement Mode: Plug-in Type;
Number of Poles: Three Pole;
Grounding: Un Grounded;
Series: Three;
Run: Plug-In;
Switching Mode: Single Throw-in;
Common Model: Is;
Structure of Operating: Manual;
Brand: Moreday;
Max. Voltage: 1000V;
Rated Current: 32A;
Waterproof Level: IP66nw;
Operating Temperature Range Relative Hum: -40°c~+70°c;
|
Type: High-voltage;
Structure: Double-column Disconnector;
Installation: Indoor High-voltage;
Operation: Electric;
Grounding Mode: Not Grounding;
Movement Mode: Horizontal Rotary Type;
Number of Poles: Optins;
Grounding: Un Grounded;
Series: Two;
Run: Turn the Horizontal;
Switching Mode: Optins;
Common Model: Mdis-40;
Structure of Operating: Electric;
Brand: Moreday;
Whether The Smart: No;
Max. Current: 32A;
Max. Voltage: 1200V;
Rated Operational Voltage: 500V,600V,800V,1000V,1200V;
Rated Current: 10A,16A,20A,25A,32A;
Number of DC Poles: 2 or 4;
Working Temperature: -40ºCTO +85ºC;
Standard: IEC60947-3,As60947.3;
|
Type: High-voltage;
Structure: Double-column Disconnector;
Installation: Indoor High-voltage;
Operation: Electric;
Grounding Mode: Not Grounding;
Movement Mode: Horizontal Rotary Type;
Number of Poles: Optins;
Grounding: Un Grounded;
Series: Two;
Run: Turn the Horizontal;
Switching Mode: Optins;
Common Model: Mdis-40MD;
Structure of Operating: Electric;
Brand: Moreday;
Whether The Smart: No;
Max. Current: 32A;
Max. Voltage: 1200V;
Rated Operational Voltage: 500V,600V,800V,1000V,1200V;
Rated Current: 10A,16A,20A,25A,32A;
Number of DC Poles: 2 or 4;
Working Temperature: -40ºCTO +85ºC;
Standard: IEC60947-3,As60947.3;
|
Type: High-voltage;
Structure: Double-column Disconnector;
Installation: Indoor High-voltage;
Operation: Electric;
Grounding Mode: Not Grounding;
Movement Mode: Horizontal Rotary Type;
Number of Poles: Optins;
Grounding: Un Grounded;
Series: Two;
Run: Turn the Horizontal;
Switching Mode: Optins;
Common Model: Mdis-40MD;
Structure of Operating: Electric;
Brand: Moreday;
Whether The Smart: No;
Max. Current: 32A;
Max. Voltage: 1200V;
Rated Operational Voltage: 500V,600V,800V,1000V,1200V;
Rated Current: 10A,16A,20A,25A,32A;
Number of DC Poles: 2 or 4;
Working Temperature: -40ºCTO +85ºC;
Standard: IEC60947-3,As60947.3;
|