Specification |
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Aed Wall Cabinet;
Group: Applicable to All;
Products Name: Aed Wall Cabinet;
Material: Metal +PC Glass;
Color: White, Green,Red, Yellow, Mix Color, etc.;
Use: Indoor Use;
Service: OEM & ODM(Size,Color,Logo etc);
Warranty: 2 Years;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: All People;
Model: Bk-200;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Sample Volume: 2~70UL;
Reagent Volume: 20~350UL;
Probe: Coating, with Anti-Collision Function, Liquid Leve;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37+0.1ºC, Real-Time Monitoring;
Cuvettes: 48 Reusable Cuvettes, Optical Length 6mm;
Mixer Probe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Stat Function: Yes;
|
Type: Urinary Sediment Analysis System;
Product Name: Urine Analysis System;
Model Number: Us-120;
After-Sale Service: Online Technical Support;
Test Speed: 120tests/Hour;
Sample Volume: >2.5ml;
Sensitivity: <10;
Pollution Rate: <0.05%;
Recognition Rate: >95%;
Counting Cell: Four Channels;
Sampling Volume: 0.5ml;
Repeatability(CV): <10%;
False Negative Rate: <3%;
|
Classification: Biological Diagnostics;
Type: Fluorescent Quantitative PCR Dtection System;
Group: All;
Product Name: Fluorescent Quantitative PCR Dtection System;
Channel: 4;
Detection Wavelength: 510~730nm;
Module Temp. Range: 4-99ºC(Resolution:0.1ºC);
Operation System: Microsoft: Windows10;
Dynamics Range: 1-1010 Copies;
Emission Light: LED;
Detection Path: F1;
Excitation Wavelength: 455~680nm;
Fluorescence Detection Repeatability: CV≤2%;
Scanning Time: 8.5s;
Power Supply: 220V,50/60Hz; 110V,60Hz;
Brand: Biobase;
Color: White;
Gross Weight: 45kg;
|
Classification: Imaging Diagnostic Equipment;
Type: Biochemistry Analyzer;
Group: All;
Model: Bk-200;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Mixer Probe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Light Source: 6V/10W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
Absorbance: 0~3.0ABS;
Gross Weight: 55kg;
|