Specification |
Classification: Imaging Diagnostic Equipment;
Type: Ultrasound Scanner;
Display Mode: B, B+B, 4b, B+M, M;
Language: Cn, En, Sp, Fr, Ru, Por;
Probe Options: Convex, Linear, Tvs, Micro-Convex;
Battery: 8800mAh;
Standby: 4-6 Hours Continuous Scan;
Monitor: 12 Inch LED;
Packing Size: 47*22*40cm;
Gross Weight: 9.5kg;
Net Weight: 4.7kg;
Ob-1: GS,Bpd,Crl,FL,Hl,Tad,LV,Ofd,AC,Hc,Afi;
Ob-2: FTA,Ttd,Aptd,Thd,Tcd,Ci,Efw,Input Lmp,Growth Curve;
|
Classification: Biochemical Apparatus;
Type: Elisa Microplate Reader;
Measurementchannel: Vertical 8 Optical Channels;;
Wavelength Range: 400-800 Nm;
Readingrange: 0.000-4.000 ABS;
Linearrange: 0.000-3.000 ABS;
Repeatability: CV≤1.0%;
Stability: ≤±0.003ABS;
Wavelengthindicationerror: ≤±2nm;
Wavelengthrepeatability: ≤±1.5nm;
Sensitivity: ≥0.01 Mg/L;
Channeldifference: ≤0.02ABS;
Display: 10.1-Inch Large Touch Screen;
Brand: Biobase;
Warranty: 1 Year;
|
Classification: Biochemical Apparatus;
Type: Elisa Microplate Reader;
Group: All;
Measurement Channel: Vertical 8 Optical Channels;
Plate Type: 96-Well Microplate;
Wavelength Range: 400 ~ 750nm;
Reading Range: 0.000 ~3.000ABS;
Linear Range: 0.000 ~3.000ABS;
Resolution: 0.0001ABS;
Repeatability: CV≤1.0%;
Stability: ≤±0.005ABS;
Sensitivity: ≥0.01 Mg/L;
Channel Difference: ≤0.02ABS;
Power Supply: AC100-240V, 50760Hz;
Instrument Size(W*D*H): 450*320*300mm;
Package Size(W*D*H): 540*400*460mm;
Net Weight: 13kg;
Gross Weight: 15kg;
|
Classification: Biochemical Apparatus;
Type: Digital Imaging System;
Group: Middle-aged and Old;
Block Formats: 96-Well;
Dynamics Range: 1-10^10 Copies;
Heating/Cooling Rate: 0.1~4.2ºC/S;
Excitation Wavelength: 300-800nm;
Emission Wavelength: 500-800nm;
Reaction System: 5~100μl;
Sample Capacity: 96X0.2ml PCR Plate, 12X8-Strip Tubes, 96*0.2ml Si;
Product Name: Fluorescence Quantitative PCR Detection System;
Ramprate: 4.0ºC/S(Max);
Temp. Control Accuracy: ±0.1ºC;
Temp. Uniformity: ≤ ±0.3ºC;
Temp. Control Mode: Block Mode Andtube Mode (Automaticcontrolbasedonli;
Operation Mode: Continuous Operation;
Gradient Temp. Range: 1-36ºC;
Hot-Lid Temp. Range: 30-110;
|
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor;
Group: All;
Sample Quantity: 32;
Status: in Stock;
Sample Volume: 20-500UL;
Sample Throughput: 1-32;
Magnetic Bead Recovery: >98%;
Extracting The Difference Between Holes: 3%;
Heating Temperature: 8 Independent Heating Modules;
Reagent Type: Magnetic Bead Open Platform;
Extraction Time: 15-40 Min/Round;
Internal Program: Be Able to Store;
|