Specification |
Classification: Imaging Diagnostic Equipment;
Type: Digital Imaging System;
Group: Female;
Model: De-610;
Camera: 1/2.8 Sony CMOS;
Image Size: 1080P;
Configuration: Lens, Software, Tripod, and Handheld Controller;
Focus Distance: 10mm~400mm;
Horizon Resolution: More Than 1200 Lines;
Total Pixels: 3,270,000 Pixels;
Scan Mode: Progressive Scan;
Light Source: LED Cold Light;
Video Output: HDMI;
|
Classification: Biological Diagnostics;
Type: Mircoplate Incubator;
Group: All People;
Model: Bk-Ts300;
Temp. Setting Range: 0ºC~80ºC;
Temp. Control Range: Rt+5ºC~80ºC;
Time Range: 1min~99h59min;
Temp. Accuracy: ≤±0.5ºC;
Display Accuracy: 0.1ºC;
Temp. Uniformity: ≤±0.5ºC;
Heating Time: ≤10min(From 25ºC to 80ºC);
Max. Height of Plate: 22mm;
Capacity: 4 Microplates or Deep Well Plates;
Power Supply: AC220V±10% 60/50Hz;110V±10%;
Net Weight: 7 Kg;
Package Size(W*D*H): 475*450*315mm;
Gross Weight: 8 Kg;
Dimension: 340*320*200mm;
|
Classification: Biological Diagnostics;
Type: Blood Gas & Electrolyte Analyzer;
Group: Middle-aged and Old;
Model: Bge-800A;
Input Parameters: Patient Temperature, Hemoglobin, Fio2, B.P.;
Analysis Time: Less Than 90s;
Sample Volume: 95μl (Whole Blood), 35μl (Capillary Blood);
Calibration: Automatic, Programmable, One-Point and Two-Point;
Data Storage: More Than 10, 000 Results;
Display: 10.4'' TFT Touch Screen;
Battery: Leadacidbattery, 2.3ah;
Printer: Build Inthermalprinter, 70mm;
Barcode Reader: up to 14 Kindsbarcodetype;
Interface: Serialline RS-232;
Powersupply: AC220±10% 50/60Hz; 110±10% 60Hz;
Temperature: 15ºC~30ºC;
Storage Environment: 5~45ºC;
Package Size(W*D*H): 320*460*370mm;
|
Classification: Fluorescence Quantitative Real-Time PCR;
Type: Fluorescence Quantitative Real-Time PCR;
Group: All;
Type for: Genes & Life Science Equipments;
Block Sample Capacity: 48-Well * 0.1ml;
Temperature Accuracy: Less Than 0.2 Degree (at 90 Degree);
Reaction Volume: 10-50UL;
Block Temperature Range: 0~105 Degree;
Display: 7'' Color TFT Touch Screen;
Tubes Option: Low-Profile White or Clear 0.1ml PCR Tube/Eight St;
Heating and Cooling Technology: The Newest Generation of Peltier Technology for Mo;
Control Methods: Operate Via PC Remote Control; or The Touch Screen;
Communications: USB 2.0 and LAN, Export Data Via USB Flash Drive;
Mode of Temperature Control: SIM-Tube & Block;
Detection: High Sensitivity Photoelectric Detector;
Calibrated Dyes at Installation: Channel 1 Fam Sybr Channel 2 Vic Hex Joe;
Fluorescence Excitation Range: 470 ~ 500nm;
Fluorescence Detection Range: Channel 1 520 ~ 540nm, Channel 2 540 ~ 700nm;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Sample Racks: Standard 192 Sample Position (Expandable, up to 38;
Pipetting: 10~1000μl;
Pipetting Range: 10~1000μl,1UL Stepping;
Pipetting Precision: (100μl) CV≤0.5%;
Dispensingtime: 5 Minutesto Whole 96 Well Microplates;
Incubation: 2 Independent Incubators;
Temperature Range: Rt to 45 °c;
Temperature Accuracy: ±0.5°c;
Washing Probes: Two Line 8-Nozzle Manifolds;
Wash Containers: 2 Wash Buffers 2L, 1 Distilled Water, 1 Waste Wate;
Washing Residual: <2μl;
|