Specification |
Application: Power, Electronic, Instrument, Lighting;
Phase: Single;
Core: Core-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EE;
Color: Grey or Optional;
Iron Core: New Silicon Steel Sheet;
Approval Company: ISO9001&CNAS;
Temperatures: -30ºC~ +40ºC;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Reference Standards: IEC 60076;
Voltage (Hv) (Kv): 11 Kv;
Core Material: Silicon Steel;
Temperature Rise (W): 60/65K;
Insulation Class: a-Class;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Rated Capacity: 500 kVA;
Cooling Way: Onan/Onaf;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Reference Standards: IEC 60076;
Voltage (Hv) (Kv): 11 Kv;
Core Material: Silicon Steel;
Temperature Rise (W): 60/65K;
Insulation Class: a-Class;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Rated Capacity: 500 kVA;
Cooling Way: Onan/Onaf;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Rated Capacity: 630 kVA;
Rated L. V.: 0.4kv;
Cooling Way: an/Af;
Core Material: Silicon Steel;
Vector Group: Dyn11;
Temperature Rise: 125K;
Accessories: Fans, Enclosure;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Cast Resin Transformer;
Reference Standards: IEC60076 / GB;
Capacity: 1000~3000kVA or Customized;
Rated H. V.: 21kV or Customized;
Rated L. V.: 0.42kV or Customized;
Impedance: 4~8%;
Cooling Way: AN/AF;
Winding: Cooper/Aluminum;
Core Material: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11 or Customized;
Insulation Class: H-Class;
Temperature Rise: 125K;
Enclosure: IP20/IP23;
Accessories: Fans, Enclosure;
|