Specification |
Classification: Imaging Diagnostic Equipment;
Type: ECG;
Group: All People;
Lead: Standard 12 Leads;
Lead Acquisition: 12 Bit/1000Hz;
Work Mode: Manual/Auto/R-R Analysis;
Calibrating Voltage: 1mv ± 2%;
Input Circuit Current: ≤0.05;
Voltage Tolerance: ≥±500mv;
Time Constant: ≥3.2s;
Frequency Response: 0.05-160Hz;
Inter-Channel Interference: ≤0.5mm;
Sensitivity: Auto 2.5,5,10,20,40mm/Mv;
Paper Speed: 6.25,12.5,25,50mm/S;
Paper: 112mm*20m High Resolution Thermal Roll Paper;
Working Environment: Temperature 5-40 Degreem,Humidity 25-95%;
Power Supply 1: AC 110-230V,50/60Hz, 40va;
Power Supply 2: DC Built-in Rechargeable Ni-Hm Battery, 120V;
|
Classification: Pathology Lab;
Type: Fully Automated Tissue/Slide Stainer;
Group: All;
Product Name: Fully Automated Tissue/Slide Stainer;
Model: Bk-Ts2;
Display: LCD Touch Screen;
Cup Number: 18 (Station 1 Is for Drying, Station 10 Is for Was;
Single Cup Capacity: 750ml;
Each Cup Processing Time: 0~59 Min;
Slides Processed Simultaneously: 52 Slides;
Dripping Time: Adjustable Within 0~30 S (Shakes Above Cup);
Consumption: 500W;
|
Classification: Infant Incubator;
Type: Infant Incubator;
Group: Infants and Young Children;
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz;
Display: LCD Display Screen;
Accuracy of Skin Temperature Sensor: +-0.3oc;
Humidity Display Range: 0%Rh~99%Rh;
Control Modes: Air Mode and Baby Mode Controlled by Micro-Compute;
Operating Temperature Range: 20oc~30oc;
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc);
|
Classification: Infant Incubator;
Type: Infant Incubator;
Group: Infants and Young Children;
Display: LCD Display Touch Screen;
Operating Temperature Range: 20oc~30oc;
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz;
Humidity Display Range: 0%Rh~99%Rh;
Control Modes: Air Mode and Baby Mode Controlled by Micro-Compute;
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc);
Accuracy of Skin Temperature Sensor: +-0.3oc;
|
Type: Auto Chemistry Analyzer;
Group: All;
Throughput: 200tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic), Turbidimetry;
Sample Positions: 49 Sample Positions;
Reagent Positions: 56 Reagent Positions;
Probewashing: Automaticwashing Interior and Exterior;
Reagentcooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37±0.1ºC, Real-Time Monitor;
Mixerprobe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Light Source: 6V/10W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,480,505,546,570,600,,630,700,750,800nm;
Absorbance: 0-3.0ABS;
Quality Control: Real-Time QC, Westgard Multi Rule, Cumulative Sum;
Software: Windows 7/8/10 , 32or 64bit;
|