Specification |
Breaking Capacity: Both;
Operation: Manual Reset /Auto Reset;
Speed: High-Speed Circuit Breaker;
Installation: Insert;
Structure: Auto;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Outlook: Blade/ Stud/ Panel Mount;
Voltage for Car: 12V 24V 48V;
Voltage for Machine: 125V 250V;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Normal Type Circuit Breaker;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Handcart/Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Handcart/Fixed;
Name: Vacuum Circuit Breaker;
Color: Red/Black/White;
Rated Voltage: 12kv;
Rated Current: 400-630;
Certufucates: ISO;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Normal Type Circuit Breaker;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Handcart/Fixed;
Name: Vacuum Circuit Breaker;
Color: Red/Black/White;
Rated Voltage: 36 40.5kv;
Rated Current: 630~1600A;
Certufucates: ISO;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Normal Type Circuit Breaker;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Handcart/Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Fixed/Handcar type;
Name: Circuit Breaker Type User Boundary Switch Breaker;
Certificates: ISO;
Packing: Carton;
Name1: Controller;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Phase: 3;
Number of Pole: Fixed;
Main Circuit Rating Voltage: 12;
Main Circuit Rating Current: 1250/1600A;
Name: Embedded poles;
Shelf life: 20years;
Afterserivce: Yes;
|