Specification |
Application: Power, Electronic;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Zhonghao;
Name: Pad Mounted Transformer Prefabricated Transformer;
Usage for: Combined Transformer, Power Transformer, Distribut;
Rated Voltage: 10kv,;
Low Voltage: 0.4kVA;
Rated Frequency: 50Hz;
Maximum Working Voltage: 12kv;
Rated Current: 630;
Model: Yb;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 400kVA;
High Voltage: 11kv;
Low Voltage: 0.4kv;
Impedance Voltage: 4%;
No-Load Loss: 0.57kw;
Load Loss: 4.52/4.3kw;
No-Load Current: 0.8%;
Frequency: 50/60Hz;
Connection Method: Yyn0/Dyn11;
Material: Aluminum/Copper;
Weight: 1430kg;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: OD;
Brand: Jiade;
Voltage: 380V;
Electric Current: 10A;
Inductance: 0.01mh;
Harmonic Component: 5%;
Insulation Class: H;
Temperature Rise: 45K;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 1250kVA;
High Voltage: 11kv;
Low Voltage: 0.4kv;
Impedance Voltage: 4%;
No-Load Loss: 1.36kw;
Load Loss: 12kw;
No-Load Current: 0.5%;
Frequency: 50/60Hz;
Connection Method: Yyn0/Dyn11;
Material: Aluminum/Copper;
Weight: 3200kg;
|
Application: Power, Electronic;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Separated Winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Honle;
Frequency: 50-60Hz;
Delivery: 30-45days;
|