Specification |
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: ECG;
Group: Middle-aged and Old;
Sampling Rate: 100 Dots/S;
Accuracy: 12bit.;
Cmrr: 90dB;
Magnification Multiple: 10000;
Filter Constant: All Digital and Free Enactment;
Play Speed: 5, 10, 15, 30, 60, 120 mm/S;
Safety Type: Class II, Type Bf Applied Part;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Hospital;
Product Name: Auto Elisa Processor;
Pipetting: 10~1000μl;
Reagent Racks: 8+1reagent Racks, Editable;
Pipetting Precision: (100UL) CV 0.5%;
Incubation: 2 Independentincubators;
Sample Racks: 80 Sample Positions(Tubes 13mm);
Dispensing System: 1 Aspirating-Dispensing Probe with X-Y-Z Movement;;
Gross Weight(Kg): 160kg;
Package Size(W*D*H)mm: 1020*810*1240mm;
Place of Origin: Shandong, China;
Model Number: Biobase-Sliver Plus;
Brand Name: Biobase;
Warranty: 1 Year;
Dispensingtime: 5 Minutesto Whole96well Microplates;
Reaction Tray: 48 Reusable Cuvettes (Optical Path Length 6mm);
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Throughput: 800tests/Hour, 1200tests/Hour with ISE(Optional);
Sample Positions: 150 Sample Positions;
Light Source: 12V/20W Halogen Lamp/Fiber Bragg Grating Optional;
Software: Windows 7/8/10 , 32or 64bit;
Reagent Position: 180reagent Positions;
Probe Washing: Automatic Washing Interior and Exterior;
Wavelength: 12 Wavelength From 340~800nm;
External Size (W*D*H): 1360*795*1155mm;
Gross Weight: 400kg;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Throughput: 1200 Test/Hour;
Sample Positions: 150sample Positions;
Light Source: 12V/30W Halogen-Tungsten Lamp;
Software: Windows 7/8/10 , 32or 64bit;
Wavelength: 12 Wavelength From 340~800nm Absorbance -0.3~3.0ab;
Probe Washing: Automatic Washing Interior and Exte;
Reagent Cooling: Refrigerated Tray with Independen;
Lis System: Bi-Direction,Support Hl7 Protocol;
|
Classification: Air Volume Meter;
Type: Air Volume Meter;
Group: All;
Air Volume Range: 150-3500m&Sup3;
Accuracy: ±5%(F•s);
Resolution: 1 M³/H;
Temp Measurement Range: 0-60ºC;
Humidity Measurement Range: 0-100%Rh;
Power Supply DC: 7.4V/1800mA;
AC: 220V±10% 50Hz±2Hz;
Storage: up to 999 Test Results;
Standard Printer: Bluetooth Printer;
Operating Environment: Temperature: 5ºC-35ºC;
Storage Environment: Temperature: -30ºC-45ºC;
Air Flow Hood: Standard: 570*570mm, 830*830mm;
Package Size: 750*750*180mm;
Gross Weight: 10kg;
Temp Measurement Accuracy: ±0.5ºC;
|