Specification |
Classification: Patient Monitor;
Type: Patient Monitor;
Group: Patient Monitor;
4 Unit Per Carton, Package Size: 58*39*75cm;
Total Gross Weight: 20 Kg;
Measurement Range: Adult: 10~ 120 Brpm;
Neonatal I Pediatric: 7 ~ 150 Brpm;
Resolution: 1 Brpm;
Accuracy: +2 Brpm;
Measure and Alarm Range: 0 ~ 50 C;
|
Classification: Biological Diagnostics;
Type: Automatic Biochemistry Analyzer;
Group: All;
Product Name: Automatic Biochemistry Analyzer;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Sample Volume: 2~70μl;
Reagent Volume: 20~350μl;
Probe: Liquid Level Sensor Function, Anti-Collision Funct;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37+0.1ºC, Real-Time Monitoring;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Light Source: 6V/10W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
|
Classification: Biological Diagnostics;
Type: Chemistry Analyzer;
Group: All;
Product Name: Auto Chemistry Analyzer;
Test Speed: 220t/H;
Analysis Method: End-Point, Fixed-Time, Rate, Turbidimetry;
Sample Positions: 49 Sample Positions, Including Calibration, Quali;
Reagent Positions: 56 Refrigerated Reagent Positions;
Sample Volume: 2UL ~70UL (0.1UL Stepping);
Reagent Volume: R1 & R2: 20UL ~350UL (1UL Stepping);
Sample & Reagent Probe: Liquid Level Sensor Function, Anti-Collision Func;
Probe Washing: Automatically Wash Interior and Exterior;
Reaction Time: 10 Minutes;
Cooling Function: 2ºC~8ºC Cooling for 24 Hours;
Temperature Control: 37ºC±0.1ºC, Real-Time Monitor;
Receiver: 8 Precision Photo Receivers;
Linear Range: 0.000~3.000ABS;
Computer System: Windows7/8/10, Lis System Available;
|
Classification: Biological Diagnostics;
Type: Automatic Chemiluminescence Immunoassay System;
Group: All;
Throughput: 120t/H;
Principle: Magnetic Particle Enzymatic Chemiluminescence;
Modes of Operation: Random, Batch and Stat;
Separation Method: Magnetic Separation Technology;
Sample Positions: 60 (Each Position Could Be Used as an Emergency Po;
Reagent Positions: 30 PCS (2-8ºC Refrigeration);
Incubation Positions: 80;
Time to 1st Result: 18 Minutes;
Sample Volume: 15-100UL;
Carry-Over Rate: Less Than10-5;
Calibration Stability: 28 Days;
Calibration Type: 6/7-Point Calibration;
Software System: Windows 7/8/10, 32 or 64 Bit;
Interface: TCP/IP Network Interface;
Power Supply: AC110/220V,50/60Hz;
|
Classification: Biological Diagnostics;
Product Name: Classic Thermal Cycler;
Model: Bk-Ai;
Standardmodule: 96 Module: 96 Wells*0.2ml or 9677module: 96 Wells*;
Language: English;
USB Flash Drive: Unlimited Storage of Protocols with USB Flash Driv;
Communications Ports: 2USB 2.0 and LAN;
Mode of Temperature Control: SIM-Tube & Block Mode;
Height of Heated Lid: Steplessly Adjustable Lid, Accommodatesall Kinds O;
Open Method: Innovative Top-Open Technology Realizesopen and Li;
|