Specification |
Theory: Electromagnetic Relay;
Usage: Car Relay, Household Appliances Relay, Communication Relay, Lathe Relay, Smart Meter;
Phase: 1;
Electricity Type: Ac;
Number of Pole: 1;
Load: Weak Power Relay;
Protective Characteristics: Enclosed Rlay;
Action Principle: Electronic Type;
Size: Miniature;
Type: Electric Parameter Relay;
Current Range: 0-100A;
Voltage: 240VAC;
Coil: Dobule;
Coil Voltage: 12VDC;
with Shunt/CT: Customized;
Supply: Jiaxing Haihan Electron Co.,Ltd;
|
Theory: Electromagnetic Relay;
Usage: Earth Fault Operated Relay;
Phase: 3;
Electricity Type: AC Type;
Number of Pole: N/a;
Load: N/a;
Protective Characteristics: N/a;
Action Principle: Electromagnetic Type;
Size: See Instruction;
Type: Electric Parameter Relay;
Operating Current: 0.03, 0.1, 0.3, 0.5(a);
Delay on Release Toff: 0.1,0.5(S);
Contact: 1no + 1changeover;
Power Supply: AC 220V, AC110V;
Non-Operating Current: 50%in;
Mounting Type: 35mm DIN Rail;
Frequency Range: 45~55Hz;
Operating Uncertainty: -20~-10%in;
Contact Data: 5A AC 250V, 5A DC 30V;
Reset: Button or Remote;
Operating Temperature: -25~+55 Degree Celsius;
Pollution Degree: III;
Overvoltage Category/: 3;
|
Theory: Electromagnetic Relay;
Usage: Earth Fault Operated Relay;
Phase: 3;
Electricity Type: AC Type;
Number of Pole: N/a;
Load: N/a;
Protective Characteristics: N/a;
Action Principle: Electromagnetic Type;
Size: See Instruction;
Type: Electric Parameter Relay;
Operating Current: 0.03, 0.1, 0.3, 0.5(a);
Delay on Release Toff: 0.1,0.5(S);
Contact: 1no + 1changeover;
Power Supply: AC 220V, AC110V;
Non-Operating Current: 50%in;
Mounting Type: 35mm DIN Rail;
Frequency Range: 45~55Hz;
Operating Uncertainty: -20~-10%in;
Contact Data: 5A AC 250V, 5A DC 30V;
Reset: Button or Remote;
Operating Temperature: -25~+55 Degree Celsius;
Pollution Degree: III;
Overvoltage Category/: 3;
|
Theory: Electromagnetic Relay;
Usage: Leakage Monitoring;
Phase: 3;
Electricity Type: AC Type;
Number of Pole: N/a;
Load: N/a;
Protective Characteristics: N/a;
Action Principle: Electromagnetic Type;
Size: See Instruction;
Type: Electric Parameter Relay;
Operating Current: 0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30(a);
Delay on Release Toff: 0,, 0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, 10(S);
Contact Data 1: 1 No or 1 Nc+ 1 Change-Over;
Power Supply: AC 85~265V;
Non-Operating Current: 50%in;
Mounting Type: Panel Mounting;
Operating Characteristic: AC and Pulsed DC Sensitive Residual Current;
Frequency Range: 45~55Hz;
Operating Uncertainty: -20~-10%in;
Contact Data 2: 8(6)a AC 250A 5A DC 30A;
Reset: Button, Remote, Auto;
Operating Temperature: -20~+55 Degree Celsius;
Communication: RS485/Modbus RTU;
Measured-Value Memory for Alarm Value: 25 Data Records;
EMC: DIN En 62020;
|
Theory: Electromagnetic Relay;
Usage: Leakage Monitoring;
Phase: 3;
Electricity Type: AC Type;
Number of Pole: N/a;
Load: N/a;
Protective Characteristics: N/a;
Action Principle: Electromagnetic Type;
Size: See Instruction;
Type: Electric Parameter Relay;
Operating Current: 0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30(a);
Delay on Release Toff: 0,, 0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, 10(S);
Contact Data 1: 1 No or 1 Nc+ 1 Change-Over;
Power Supply: AC 85~265V;
Non-Operating Current: 50%in;
Mounting Type: Panel Mounting;
Operating Characteristic: AC and Pulsed DC Sensitive Residual Current;
Frequency Range: 45~55Hz;
Operating Uncertainty: -20~-10%in;
Contact Data 2: 8(6)a AC 250A 5A DC 30A;
Reset: Button, Remote, Auto;
Operating Temperature: -20~+55 Degree Celsius;
Communication: RS485/Modbus RTU;
Measured-Value Memory for Alarm Value: 25 Data Records;
EMC: DIN En 62020;
|