Specification |
Application: Power;
Phase: Three;
Core: Three Dimensional Core;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Three Dimensional;
Brand: Han's Power;
High Voltage: 35/11/10.5/10/6.6/6.3/6 Kv;
Low Voltage: 0.4kv;
Winding Material: Copper / Aluminum;
Vector Group: Dyn11;
Tapping Range: ±2X2.5%;
Frequency: 50/60 Hz;
Shipping Port: Shanghai / Ningbo / Guangzhou / Shenzhen...;
OEM/ODM Service: Provided;
|
Application: Power, Electronic;
Cooling Method: Oil-immersed Type Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Power Loss: No-Load Loss Is 30% Lower Saving Than Standard;
Material: Oil, CRGO, Copper;
Color: Standard Grey in Default;
High Voltage: 6 6.3 10 10.5 11;
Medium Voltage: ±5% or ±2×2.5%;
Low Voltage: 0.4;
Connection Symbol-1: 30-500kVA Is Dyn11 Yyn0 Yzn11;
Connection Symbol-2: Above 500kVA Is Dyn11 Yyn0;
Warranty: 12 Months;
Design Capacity: up to 200mva;
No-Load Loss Range: 12~67.7kw or Customized;
Load Loss: 47~270kw or Customized;
No-Load Current: 0.6~0.30% or Customized;
Tap-Changing: on-Load Tap-Changing or off-Load Tap-Changing;
Sound Level: 35~50dB Range;
|
Application: Power, Electronic;
Cooling Method: Oil-immersed Type Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Power Loss: No-Load Loss Is 30% Lower Saving Than Standard;
Material: Oil, CRGO, Copper;
Color: Standard Grey in Default;
High Voltage: 6 6.3 10 10.5 11;
Medium Voltage: ±5% or ±2×2.5%;
Low Voltage: 0.4;
Connection Symbol-1: 30-500kVA Is Dyn11 Yyn0 Yzn11;
Connection Symbol-2: Above 500kVA Is Dyn11 Yyn0;
Warranty: 12 Months;
Design Capacity: up to 200mva;
No-Load Loss Range: 12~67.7kw or Customized;
Load Loss: 47~270kw or Customized;
No-Load Current: 0.6~0.30% or Customized;
Tap-Changing: on-Load Tap-Changing or off-Load Tap-Changing;
Sound Level: 35~50dB Range;
|
Application: Power, Electronic;
Cooling Method: Oil-immersed Type Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Power Loss: No-Load Loss Is 30% Lower Saving Than Standard;
Material: Oil, CRGO, Copper;
Color: Standard Grey in Default;
High Voltage: 6 6.3 10 10.5 11;
Medium Voltage: ±5% or ±2×2.5%;
Low Voltage: 0.4;
Connection Symbol-1: 30-500kVA Is Dyn11 Yyn0 Yzn11;
Connection Symbol-2: Above 500kVA Is Dyn11 Yyn0;
Warranty: 12 Months;
Design Capacity: up to 200mva;
No-Load Loss Range: 12~67.7kw or Customized;
Load Loss: 47~270kw or Customized;
No-Load Current: 0.6~0.30% or Customized;
Tap-Changing: on-Load Tap-Changing or off-Load Tap-Changing;
|
Application: Power, Electronic;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Power Loss: No-Load Loss Is 30% Lower Saving Than Standard;
Material: Oil, CRGO, Copper;
Color: Standard Grey in Default;
High Voltage: 6 6.3 10 10.5 11;
Medium Voltage: ±5% or ±2×2.5%;
Low Voltage: 0.4;
Connection Symbol-1: 30-500kVA Is Dyn11 Yyn0 Yzn11;
Connection Symbol-2: Above 500kVA Is Dyn11 Yyn0;
Warranty: 12 Months;
Design Capacity: up to 200mva;
No-Load Loss Range: 12~67.7kw or Customized;
Load Loss: 47~270kw or Customized;
No-Load Current: 0.6~0.30% or Customized;
Tap-Changing: on-Load Tap-Changing or off-Load Tap-Changing;
|