Specification |
Warranty: 1 Year;
Product Name: Precision Metal Sample Cutting Machine;
Maximum Cutting Section: Diameter 85mm;
Cutting Wheel Size: 300 X 2 X 32mm;
Speed: 2800r/Min;
Quick Clamping: Yes;
Cooling: Water Cooling;
Structure: Closed Structure, Large Observation Window;
Function: Metallographic Labs Sample Preparation Use;
Easy Clean: with a Flush Nozzle;
|
After-sales Service: Permanent;
Warranty: 1 Year;
Product Name: Tuning Fork Level Switch;
Output: Spdt Relay, Dpdt, Spst or PNP/NPN;
Power Supply: 220VAC/24VDC;
Working Temperature: Fork Body -30~150ºC; Instrument -30~70ºC;
Working Pressure: Less Than 2MPa;
Media Density: Minimum 0.6g/Cm³;
Action Point: Vertically Inserted Into The Water at About 22mm;
Hysteresis Setting: About 3mm;
Wetted Material: SUS304, SUS316L, Stainless Steel Sprayed with PTFE;
Electrical Interface: M20×1.5;
Keyword: Limit Switch Sensor;
|
After-sales Service: 12 Months;
Sensor Probe Type: Internal Probe;
Measurement Range: 0~2000μm;
Measuring Principle: Fe: Magnetic Induction ; Nfe: Eddy Currents;
Accuracy: ±(3%+1μm);
Resolution: 0.1μm(0~100μm) ; 1μm(>100μm);
Calibration: Zero Calibration ; Multi-Point Calibration;
Reading Memory: 10X13X10 Measurement Data;
Statistic: Number of Data, Maximum, Minimum, Mean, Sample Sta;
Probe Trigger Mode: Mechanical Trigger, Trigger Force: 0.4~0.8n;
Minimum Curvature Radius: Convex 5mm ; Concave 25mm;
Minimum Measuring Area: Diameter 15mm;
Minimum Thickness of Substrate: Fe: 0.30mm Nfe: 0.05mm;
|
After-sales Service: 12 Months;
Sensor Probe Type: External Separated Probe;
Measurement Range: 0~2000μm;
Measuring Principle: Fe: Magnetic Induction ; Nfe: Eddy Currents;
Accuracy: ±(2%+1μm);
Resolution: 0.1μm(0~100μm) ; 1μm(>100μm);
Calibration: Zero Calibration ; Multi-Point Calibration;
Reading Memory: 10X13X10 Measurement Data;
Statistic: Number of Data, Maximum, Minimum, Mean, Sample Sta;
Probe Trigger Mode: Mechanical Trigger, Trigger Force: 0.4~0.8n;
Minimum Curvature Radius: Convex 5mm ; Concave 25mm;
Minimum Measuring Area: Diameter 15mm;
Minimum Thickness of Substrate: Fe: 0.20mm Nfe: 0.03mm;
Maximum Measuring Rate: 2 Readings / S;
Display: 2 Inch Color Screen;
Bluetooth & APP: Support;
|
After-sales Service: 12 Months;
Sensor Probe Type: Internal Probe;
Measurement Range: 0~2000μm;
Measuring Principle: Fe: Magnetic Induction ; Nfe: Eddy Currents;
Accuracy: ±(3%+1μm);
Resolution: 0.1μm(0~100μm) ; 1μm(>100μm);
Calibration: Zero Calibration;
Reading Memory: 10X13X10 Measurement Data;
Maximum Measuring Rate: 2 Readings / S;
Probe Trigger Mode: Mechanical Trigger, Trigger Force: 0.5~1.2n;
Minimum Curvature Radius: Convex 5mm / Concave 25mm;
Minimum Measuring Area: Diameter 15mm;
Minimum Thickness of Substrate: Fe: 0.30mm Nfe: 0.05mm;
Display: 128X48 DOT Matrix LCD Display, with Backlight;
|